Determination of carbaryl by flow injection with luminol chemiluminescence inhibition detection

Buy Article:

$61.00 + tax (Refund Policy)

A flow-injection procedure is described for the determination of carbaryl based on its inhibition effect on luminol-cobalt(II) chemiluminescence reaction in alkaline medium in the presence of hydrogen peroxide. The calibration data over the range 5.0 × 10-7 to 20 × 10-6 M give a correlation coefficient (r2) of 0.9972 with relative standard deviations (RSD; n = 4) in the range of 1.0-2.1% with a limit of detection (3 × blank noise) of 2.37 × 10-7 M for carbaryl. The sample throughput was 120 h-1. The effects of some carbamates, anions, and cations were studied on luminol CL system for carbaryl determination. The proposed method has been applied to determine carbaryl in natural waters.
No Reference information available - sign in for access.
No Citation information available - sign in for access.
No Supplementary Data.
No Article Media
No Metrics

Keywords: Carbaryl; Chemiluminescence; Flow-injection analysis; Inhibition

Document Type: Research Article

Affiliations: Department of Chemistry, University of Balochistan, Quetta, Pakistan