Preconcentration of Trace Arsenite and Arsenate with Titanium Dioxide Nanoparticles and Subsequent Determination by Silver Diethyldithiocarbamate Spectrophotometric Method
Authors: Xiao, Yabing; Ling, Jie; Qian, Shahua; Lin, Anqing; Zheng, Wenjie; Xu, Weiya; Luo, Yuxuan; Zhang, Man
Source: Water Environment Research, Volume 79, Number 9, September 2007 , pp. 1015-1022(8)
Publisher: Water Environment Federation
- Water Environment Research® (WER®) publishes peer-reviewed research papers, research notes, state-of-the-art and critical reviews on original, fundamental and applied research in all scientific and technical areas related to water quality, pollution control, and management. An annual Literature Review provides a review of published books and articles on water quality topics from the previous year. Published as: Sewage Works Journal, 1928 - 1949; Sewage and Industrial Wastes, 1950 - 1959; Journal Water Pollution Control Federation, 1959 - Oct 1989; Research Journal Water Pollution Control Federation, Nov 1989 - 1991; Water Environment Research, 1992 - present.
- Editorial Board
- Information for Authors
- Submit a Paper
- Subscribe to this Title
- Membership Information
- Information for Advertisers
- WEFTEC Water Quality Conference
- WEF Bookstore
- In this: publication
- By this: publisher
- In this Subject: Earth and Environmental Sciences , General & Civil Engineering , Hydraulic & Environmental Engineering
- By this author: Xiao, Yabing ; Ling, Jie ; Qian, Shahua ; Lin, Anqing ; Zheng, Wenjie ; Xu, Weiya ; Luo, Yuxuan ; Zhang, Man
Content Key:
- Free
- New
- Open Access
- Subscribed
- Free Trial
Abstract:
A novel method of preconcentration of trace arsenite and arsenate by using titanium dioxide nanoparticles as adsorbent was described. The concentrations of preconcentrated arsenite and arsenate were determined by a silver diethyldithiocarbamate spectrophotometric method without desorption. Batch adsorption experiments were carried out as a function of the pH, contact time, amount of titanium dioxide nanoparticles, and solution volume. In the pH range 5 to 6, adsorption rates of arsenite and arsenate were higher than 98%. The calibration coefficient was 0.9991, and the linear range was 0 to 100 μg/L. The developed method was precise, with the relative standard deviation <5% at concentration level of 10 μg/L, with a detection limit (3σ, n = 6) of 0.44 μg/L. The accuracy of the method for total arsenic was validated by standard reference materials (SRM 3103a) (National Institute of Standards and Technology, Gaithersburg, Maryland). The method was also applied to the analysis of arsenite and arsenate in natural water samples to verify the accuracy. The recovery values remained in a narrow range, from 95 to 103%.Keywords: arsenite; arsenate; titanium dioxide nanoparticles; silver diethyldithiocarbamate spectrophotometric m
Document Type: Research article
DOI: 10.2175/106143007X183998
Content Key:
- Free
- New
- Open Access
- Subscribed
- Free Trial

Click here for Page Help