Skip to main content

Using the Checkpoint Bioassay To Increase UV System Energy Efficiency

Buy Article:

$9.50 plus tax (Refund Policy)

Or sign up for a free trial

Checkpoint Bioassay testing was conducted on the existing Ozonia Aquaray 40 HO VLS ultraviolet disinfection system (UV system) that is installed at the El Dorado Irrigation District (EID) (Placerville, California) Deer Creek Wastewater Treatment Plant. Based upon the prior testing of the Ozonia reactor, it must operate with an assumed UVT value of 55 or 65 percent, whichever is more conservative. The operation of the UV system is controlled by a programmable logic controller (PLC), that uses a step function consisting of two equations. The first equation controls system performance when the UVT is between 55 percent and 64.9 percent, while the second equation controls the UV system when the UVT is ≥ 65 percent. Operation is not allowed if the UVT drops below 55 percent. The purposes of this testing were 1) to characterize and document the performance of the UV system at high ultraviolet light transmittance (UVT) values (i.e., 77 percent) and 2) to utilize the results from the testing to generate a single equation that could be used for energy efficient system control. Because of this checkpoint bioassay testing, UV system performance at the higher UVT values was demonstrated. The results from this testing resulted in the developement of a single control equation that allowed the system to operate at UVT values ranging from 55 to 77 percent. Use of this newly developed equation will result in an estimated annual savings of almost 31,000 in energy and lamp costs to the EID.
No Reference information available - sign in for access.
No Citation information available - sign in for access.
No Supplementary Data.
No Data/Media
No Metrics

Document Type: Research Article

Publication date: 2008-01-01

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    A subscription to the Proceedings of the Water Environment Federation includes access to most papers presented at the annual WEF Technical Exhibition and Conference (WEFTEC) and other conferences held since 2000. Subscription access begins 12 months after the event and is valid for 12 months from month of purchase. A subscription to the Proceedings of the Water Environment Federation is included in Water Environment Federation (WEF) membership.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access. Access begins 12 months after the conference or event
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • Learn about the many other WEF member benefits and join today
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more