Development of Instrument Calibration Method for Dynamic Olfactometers

Buy Article:

$17.50 plus tax (Refund Policy)

Or sign up for a free trial

Uncertainty in odour measurement is a major concern to environmental regulators, researchers, and stakeholders. Instrument and sensory performances are the two major components in estimating the uncertainty. The Australian standard in odour measurement using the dynamic olfactometer has introduced the need for instrument calibration for the first time. The paper reviews a number of olfactometers used in the last thirty years both in Australia and overseas, with particular focus on instrument performance in delivering dilution ratios. According to their gas mixing mechanism, these olfactometers were categorised into three generations. Both first generation (static mixing) and second generation (rotameter based) olfactometers are unable to meet the instrument performance criteria due to their manual operation. Third generation (mass flow controller based) olfactometers are sensitive to the supply air pressure and the back pressure caused by the gas mixing and sniffing. These mass flow controllers are susceptible to contamination that could contribute a significant error in the testing results. Several odor measurement standards around the world do not prescribe instrument calibration. Only one standard requires sensory calibration while others did not specify any instrument performance criteria. This study proposes a simple and reliable calibration method using mass flow meters. The method measured both diluted flow rate and sample flow rate in order to determine the dilution ratio. The calibration results demonstrate compliance of the olfactometer to the instrument performance criteria as specified in the standards (instability of 5% and accuracy of 20% at the 95% confidence level). The method was also used to verify the dilution ratios during the operation of the olfactometer. Instrument calibration should be carried out by the odour testing laboratory to reduce uncertainty in the measurement results.
No Reference information available - sign in for access.
No Citation information available - sign in for access.
No Supplementary Data.
No Data/Media
No Metrics

Document Type: Research Article

Publication date: 2008-01-01

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    A subscription to the Proceedings of the Water Environment Federation includes access to most papers presented at the annual WEF Technical Exhibition and Conference (WEFTEC) and other conferences held since 2000. Subscription access begins 12 months after the event and is valid for 12 months from month of purchase. A subscription to the Proceedings of the Water Environment Federation is included in Water Environment Federation (WEF) membership.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access. Access begins 12 months after the conference or event
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • Learn about the many other WEF member benefits and join today
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more