Henderson's New Membrane Bioreactor Water Reclamation Facility – Choosing and Applying the Control System Architecture

Buy Article:

$17.50 plus tax (Refund Policy)

Or sign up for a free trial


The City of Henderson, Nevada is planning a new water reclamation facility that will serve the needs of its growing population. For this new satellite 8 million gallon per day (mgd) water reclamation facility, a membrane bioreactor (MBR) treatment alternative was selected. The configuration and operation of MBR facilities require careful selection of the control system architecture, including integration of the membrane equipment supplier controls with overall treatment plant processes, key data emulation methods, and a high reliability and redundancy configuration.

The system configuration has been based on MBR control system experience and was integrated into the procurement documents for the membrane equipment supplier, including requirements for support in the control system data emulation and integration throughout the plant control system.

The main concepts for the control system architecture are:

Programmable Logic Controller (PLC) System Design

Operator Interface Modules for Monitoring and Control

Network Communications System Design

Alarm and Response Management

Standby Power

This type of 5th generation MBR system requires multiple PLCs, and the configuration of the PLCs, I/Os, and control logic within each is important. The design includes redundant master PLCs as well as train PLCs, with the coordinating logic and control of utility services (air supply, chemical feed) resident in the masters while each train PLC acts as a slave and provides control of one or more individual trains of equipment.

Network communications between PLCs and with peripheral devices such as Operator Interfaces and plant SCADA systems must be maintained, since the master PLC must be able to initiate and coordinate certain train PLC events such as backpulsing, relax, flow setpoint adjustment, and recovery clean events. Fully looped redundant communications networks are required to ensure that there cannot be a single point of failure that would disrupt communications between the master and train PLCs.

Document Type: Research Article


Publication date: January 1, 2008

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access.
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • ingentaconnect is not responsible for the content or availability of external websites

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more