From Gas to Liquid: Large-Scale Chlorination System Conversion

Buy Article:

$9.50 plus tax (Refund Policy)

Or sign up for a free trial

A number of wastewater treatment facilities using gas disinfection have decided to convert to liquid disinfection for several reasons including safety, regulatory, security, and economic factors. An optimal technology plan should be developed to facilitate the conversion. This presentation provides a case study of a large chlorine disinfection system, and demonstrates key issues of a full-scale conversion. The San Jose/Santa Clara Water Pollution Control Plant (SJ/SC WPCP) currently uses chlorine and sulfur dioxide gases for several disinfection applications including final effluent (annual dry weather flow of 135mgd and peak wet weather flow of 350 mgd). There is a substantial safety concern regarding the storage and use of the chorine and sulfur dioxide because both gases are extremely toxic and the potential for an accidental release remains as long as these two chemicals are used for disinfection. Implementation of a Risk Management Plan (RMP) demands organizational resources and associated costs (~12 percent of the current annual O&M cost). Continued use of the existing gas disinfection facility requires improvements to meet more than just basic security needs. Provisions are required to provide high-level security against potential purposeful acts. An in-depth evaluation of disinfection alternatives has led to the decision that the optimal approach for the plant final effluent disinfection is "to convert gas to liquid". The goal of the conversion is to completely eliminate chlorine and sulfur dioxide gases from the SJ/SC WPCP and provide facilities for applications of liquid sodium hypochlorite and sodium bisulfite. A gas conversion implementation plan was developed to expedite the full-scale conversion. The plant consumes more than 4,100 lbs of chlorine and 1,250 gallons of 25% sodium bisulfite on average daily basis. During peak wet weather flow period, the chlorine consumption is as high as 70,000 lbs per day and sodium bisulfite 17,000 gallons per day.
No Reference information available - sign in for access.
No Citation information available - sign in for access.
No Supplementary Data.
No Data/Media
No Metrics

Keywords: CHLORINATION; CONVERSION; DISINFECTION

Document Type: Research Article

Publication date: 2007-10-13

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    A subscription to the Proceedings of the Water Environment Federation includes access to most papers presented at the annual WEF Technical Exhibition and Conference (WEFTEC) and other conferences held since 2000. Subscription access begins 12 months after the event and is valid for 12 months from month of purchase. A subscription to the Proceedings of the Water Environment Federation is included in Water Environment Federation (WEF) membership.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access. Access begins 12 months after the conference or event
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • Learn about the many other WEF member benefits and join today
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more