Primary Drinking Water from Wastewater Effluent: Pilot Test Experience at the Miami Dade South District WWTP

Buy Article:

$9.50 plus tax (Refund Policy)

Or sign up for a free trial

The Miami-Dade Water and Sewer Department (MDWASD) owns and operates the South District Wastewater Treatment Plant in Goulds, Florida. This is a 225 mgd peak flowrate secondary oxygen activated sludge treatment facility that discharges effluent via deep injection wells. Based upon the detection of nitrogen species in the monitoring wells for the deep injection well system, MDWASD entered into a Consent Order with the Florida Department of Environmental Protection (FDEP) to address these concerns. The Consent Order requires a significant increase in the level of treatment for the facility. The resulting effluent standards and requirements for this facility include high level disinfection (HLD) as defined by the FDEP, Primary Drinking Water Standards, addressing peak flowrates, and future participation in the Comprehensive Everglades Restoration Program (CERP).

Primary Drinking Water Standards were addressed by a series of analytical efforts plus the implementation of an anoxic zone in the fifth of six stages of the oxygenation tanks at this facility. Peak flowrates were analyzed and are being addressed in the near term via secondary treatment plus HLD treatment for 285 mgd of peak hourly flowrate, and in the future, via the use of high rate clarifiers plus HLD treatment for peak flowrates above 285 mgd and up to a potential future peak hourly flowrate of 450 mgd. HLD standards per the regulations are based around filtration to less than 5 mg/l of TSS on a continuous basis plus disinfection. With the need for continuous compliance to a standard that has typically only been applied to reuse systems, which typically have alternate means of effluent disposal, it was apparent that these conditions were unique.

To address the unique circumstances, a literature search and review of similar facilities was performed. These investigations resulted in the need to pilot test deep bed sand and disk filtration processes in order to confirm potential for continuous compliance and define appropriate design criteria.

Initial pilot test screening of these two alternative filtration approaches resulted in elimination of the disk filters from further consideration and testing since the data did not support compliance at “acceptable” loading rates (3 gpm/sf and higher). Deep bed mono-media sand filter tests resulted in supporting their application for this HLD upgrade and the use of a 6 gpm/sf hydraulic loading rate as a full-scale demonstration design value. The Consent Order allows this one year demonstration with a recommended loading rate with possible, subsequent process supplementation. Criteria from the pilot testing also supported the need to ensure about 15 % redundancy of filters, plus capability to backwash and air scour up to 15% of the filters to address solids and minimize the potential for filter plugging. On-line TSS metering devices were also tested. Results of this testing indicated benefit for control of pilot filter target influent TSS levels, but inconclusive data for filter effluent TSS monitoring. The data indicated that the on-line TSS meters should be further tested in the full-scale system with less variability of loading conditions and generally better and more focused control of the meters.
No Reference information available - sign in for access.
No Citation information available - sign in for access.
No Supplementary Data.
No Data/Media
No Metrics

Document Type: Research Article

Publication date: 2006-01-01

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    A subscription to the Proceedings of the Water Environment Federation includes access to most papers presented at the annual WEF Technical Exhibition and Conference (WEFTEC) and other conferences held since 2000. Subscription access begins 12 months after the event and is valid for 12 months from month of purchase. A subscription to the Proceedings of the Water Environment Federation is included in Water Environment Federation (WEF) membership.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access. Access begins 12 months after the conference or event
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • Learn about the many other WEF member benefits and join today
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more