Skip to main content

Manipulating Head Loss to Improve Disinfection Efficiency of UV Reactors

Buy Article:

$17.50 plus tax (Refund Policy)

Or sign up for a free trial

Abstract:

The ideal hydraulic behavior for UV reactors is generally considered to be near plug-flow with effective lateral or transverse mixing. Typically, head loss increases as the transverse mixing increases and vice versa. Accordingly, head loss is a critical factor in determining a UV disinfection system's design application. Head loss is typically caused by friction and turbulence created as water flows through the reactor channel or is redirected or affected by reactor components such as lamps and deflectors. Extremely high head loss in a UV system can result in a loss of disinfection or in an upset of upstream processes such as clarification and/or filtration. Therefore, head loss through a UV reactor is most frequently associated with negative connotations. Seldom considered is the beneficial effect on disinfection efficiency due to head loss gain associated with increased transverse mixing. This paper illustrates the ability to increase the disinfection performance of UV reactors by manipulating the head loss associated with cross-flow lamp arrays.

Examination of head loss and Reynolds number on an open-channel vertical lamp system indicates that turbulent hydraulic conditions are created under typical operating conditions, which provides for effective mixing and subsequent high reactor performance. Dose-flow curves generated during bioassay validation testing of the same type of reactor revealed that disinfection efficiency improved with increasing flow. In a separate evaluation focusing on the impact of the side deflectors, results indicate that the vertical deflectors increase the disinfection efficiency of the reactor by adding turbulent hydraulics while concurrently increase the head loss. Past research is reviewed to access the sensitivity of reactor performance to approach.

The paper will demonstrate that head loss “payments”, while certainly an important design parameter, can generate a “return on investment” via the opportunity to lower O&M costs due to the gain in disinfection performance resulting from the efficient design of UV reactors employing cross-flow lamp arrays.

Document Type: Research Article

DOI: http://dx.doi.org/10.2175/193864705783978375

Publication date: January 1, 2005

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access.
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • ingentaconnect is not responsible for the content or availability of external websites
wef/wefproc/2005/00002005/00000001/art00075
dcterms_title,dcterms_description,pub_keyword
6
5
20
40
5

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more