ACUTE TOXICITY TESTING OF ALTERNATIVE HIGH-RATE DISINFECTION TECHNOLOGIES FOR CSO TREATMENT IN NEW YORK CITY

The full text article is not available for purchase.

The publisher only permits individual articles to be downloaded by subscribers.

or click here to sign up for a free trial

Abstract:

As part of the design upgrade for the New York City Department of Environmental Protection's (NYCDEP) Spring Creek Auxiliary Wastewater Pollution Control Plant (AWPCP), an existing combined sewer overflow (CSO) detention and treatment facility, a field pilot study was performed to evaluate alternative technologies for CSO wastewater disinfection. Previous pilot testing had identified applicable high-rate CSO disinfection technologies, however there was limited data on the marine toxicity of residuals and byproducts from CSO disinfection. This study evaluated the acute toxicity of CSO treated via ultraviolet irradiation (UV), chlorination/dechlorination, and chlorine dioxide. Other objectives of the study included optimization of disinfection performance, evaluation of mixing and contacting configurations, and testing of an innovative chlorine dioxide generator. However, this paper will address the results of the effluent toxicity analyses.

Three pilot scale disinfection systems (UV, chlorination/dechlorination, and chlorine dioxide) were operated concurrently on the same wastewater feed during both dry weather and wet weather conditions to simulate the range of wastewater quality considered “typical” of CSO for the Spring Creek facility. The pilot units employed high-rate treatment processes applicable to CSO including medium pressure-high intensity UV and high-rate mixing/short detention times (i.e., 5-minutes) for chemical disinfection. The units were operated over a range of dosages (UV: 46 to 173 mWs/sq.cm.; chlorination: 18 to 28 mg/l; chlorine dioxide: 6 to 10 mg/l) and test conditions which were selected from the first phase of testing. Eight separate test events were performed, 4 during wet weather CSO conditions and 4 during dry weather conditions. Sampling was performed to characterize influent wastewater quality, unit treatment performance, effluent disinfection residuals/byproducts, and effluent toxicity.

The toxicity analyses included field and laboratory toxicity measurements using bioluminescent bacteria (i.e., Microtox), and off-site laboratory analysis of 48-hour acute whole effluent toxicity (WET) using opossum shrimp and sheepshead minnow as indicator species.

WET results showed no correlation to either disinfectant dose or wet/dry weather events. Toxicity effects observed in the treated effluents were associated with the untreated wastewater rather than the disinfection processes. The results showed poor correlation between Microtox analyses taken in the field versus the off-site laboratory WET analyses.

Document Type: Research Article

DOI: http://dx.doi.org/10.2175/193864700785372019

Publication date: January 1, 2000

More about this publication?
  • Proceedings of the Water Environment Federation is an archive of papers published in the proceedings of the annual Water Environment Federation® Technical Exhibition and Conference (WEFTEC® ) and specialty conferences held since the year 2000. These proceedings are not peer reviewed.

    WEF Members: Sign in (right panel) with your IngentaConnect user name and password to receive complimentary access.
  • Subscribe to this Title
  • Membership Information
  • About WEF Proceedings
  • WEFTEC Conference Information
  • Ingenta Connect is not responsible for the content or availability of external websites

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Partial Open Access Content
Partial Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more