Abstract:

A useful formula for calculation of the external resistance, added (per phase) to the rotor of an induction motor, is derived. The criterion is to decrease the starting current of the motor in a prescribed proportion.

Keywords: external rotor resistance; induction motor; power systems; starting current

Document Type: Research Article

DOI: http://dx.doi.org/10.1080/15325000691001449

Affiliations: Electrical Engineering Department, Ben-Gurion University, Beer-Sheva, Israel