Free Content A controlled experimental model of revision implants: Part I. Development

Authors: Bechtold J. E; Kubic V.; Søballe K.

Source: Acta Orthopaedica Scandinavica, Volume 72, Number 6, 1 December 2001 , pp. 642-649(8)

Publisher: Taylor and Francis Ltd

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

We investigated the roles of particulate matter with unstable implant, in engendering the aggressive tissue response associated with implant loosening in humans. This study serves as a basis for establishing a controlled animal model to reproduce the conditions present after implant loosening. The model includes a 6 mm polymethylmethacrylate (PMMA) cylinder concentrically pistoning 500 mum under load in a 0.75-mm circumferential gap, inserted into canine medial femoral condyles for 8 weeks. We evaluated two size concentrations of polyethylene: type A particulate polyethylene (0.5-12 mum), and type B particulate polyethylene (0.5-50 mum; 85% < 12 mum). The following three treatment groups were investigated in 28 unstable implants in 14 dogs: (1) without polyethylene (control), (2) with type A polyethylene, and (3) with type B polyethylene. We found an aggressive periprosthetic membrane, similar to that seen at revision in humans, only in the unstable implant with polyethylene. The features of this membrane included macrophages with intracellular polyethylene, a dense fibrous membrane with a synovial-like lining layer, and a sclerotic neocortex. The size distribution of the polyethylene did not alter the tissue response. An unstable implant without polyethylene resulted in a benign, quiescent membrane with loose fibrous connective tissue. The model creates a revision cavity analogous to that seen in revision joint arthroplasty, and merits further studies of revision joint replacement.

Language: English

Document Type: Research article

Free content The full text is free.

View now:
download A controlled experimental model of revision implants: Part I. Development

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A