Skip to main content

Research on Lateral Shearing Interferometer for Field Monitoring of Natural Gas Pipeline Leak

Buy Article:

$28.00 + tax (Refund Policy)

Aimed at the mechanical scanning spectroscopy equipment with poor anti-interference and anti-jamming ability, which affects the accuracy of its natural gas pipeline leak detection in the wild, a new type of lateral shearing interferometer system was designed. The system uses a beam splitter to get optical path difference by a mechanical scanning part, and it cancel the introduction of external vibration interference through the linkage between the two beam splitterw. The interference intensity of interference fringes produced was calculated, and analysis of a rotating beam splitter corresponds to the angle of the optical path difference function, solving for the maximum angle of the forward rotation and reverse rotation, which is the maximum optical path range. Experiments using the gas tank deflated simulated natural gas pipeline leak process, in the interference conditions, and the test data of the type WQF530 spectrometer and the new type of lateral shearing interferometer system were comparedt. The experimental results show that the relative error of both systems is about 1% in indoor conditions without interference. However, in interference environment, the error of WQF530 type spectrometer becomes larger, more than 10%, but the error of the new type of lateral shearing interferometer system is still below 5%. The detection accuracy of the type WQF530 spectrometer decreased significantly due to the environment. Therefore, the seismic design of the system can effectively offset power deviation and half-width increases of center wavelength caused by external interference, and compared to conventional mechanical scanning interferometer devices the new system is more suitable for field detection.

Keywords: Anti-vibration; Concentration of CH4; Lateral shearing interferometer; Spectrum detection

Document Type: Research Article

Publication date: 01 September 2012

More about this publication?
  • Spectroscopy and Spectral Analysis, founded in 1981, is sponsored by the Chinese Central Iron & Steel Research Institute. "Spectroscopy and Spectral Analysis" has been indexed in SCI(1999), Ei(1992), MEDLINE(1999), and AJ (1999). "Spectroscopy and Spectral Analysis" publishes original contributions on various fields in Spectroscopy, including research results on laser spectroscopy, IR, Ramn, UV/Vis, Optical Emission, Absorption and Fluorescence spectroscopy, X-ray Fluorescence, and Spectrochemical Analysis, as well as Reseach paper, Research notes, Experimental Technique and Instrument, Review and Progress on the latest development of spectroscopy and spectrochemical anlysis, etc. "Spectroscopy and Spectral Analysis" is published monthly by Peking University Press with book sizes of large 16-mo format , and 292 pages per issue.
  • Editorial Board
  • Submit a Paper
  • Ingenta Connect is not responsible for the content or availability of external websites
  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content