Dependence of Signal on Depth in Transmission Raman Spectroscopy
Authors: Matousek, Pavel1; Everall, Neil2; Littlejohn, David3; Nordon, Alison3; Bloomfield, Matthew4
Source: Applied Spectroscopy, Volume 65, Issue 7, Pages 194A-212A and 699-824 (July 2011) , pp. 724-733(10)
Publisher: Society for Applied Spectroscopy
Abstract:
Recently, transmission Raman spectroscopy has been shown to be a valuable tool in the volumetric quantification of pharmaceutical formulations. In this work a Monte Carlo simulation and experimental study are performed to elucidate the dependence of the Raman signal on depth from the viewpoint of probing pharmaceutical tablets and powders in this experimental configuration. The transmission Raman signal is shown to exhibit a moderate bias toward the center of the tablets and this can be considerably reduced by using a recently developed Raman signal-enhancing concept, the “photon diode. The enhancing element not only reduces the bias but also increases the overall Raman signal intensity and consequently improves the signal-to-noise ratio of the measured spectrum. Overall, its implementation with appropriately chosen reflectivity results in a more uniform volumetric sampling across the half of the tablet where the photon diode is used (or across the tablet's entire depth if two photon diodes are used on each side of tablet) and enhanced overall sensitivity. These findings are substantiated experimentally on a segmented tablet by inserting a poly(ethelyne terephthalate) (PET) film doped with TiO2 at different depths and monitoring its contribution to the overall transmission Raman signal from the segmented tablet. The numerical simulations also indicate considerable sensitivity of the overall Raman signal to the absorption of the sample, which is in line with large migration distances traversed by photons in these measurements. The presence of sample absorption was shown numerically to reduce the signal enhancement effect while the overall depth-dependence profile remained broadly unchanged. The absorption was also shown to produce a depth profile with the photon diode similar to that without it, although with a reduced absolute intensity of Raman signals and diminished enhancement effect.Keywords: TRANSMISSION RAMAN SPECTROSCOPY; QUANTITATIVE ANALYSIS; PHARMACEUTICAL FORMULATIONS; DEPTH DEPENDENCE; QUALITY CONTROL; PHOTON DIODE
Document Type: Research article
DOI: http://dx.doi.org/10.1366/11-06259
Affiliations: 1: Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, Harwell Oxford, Didcot, OX11 0QX, UK; Light Systems Ltd, The Electron Building, Fermi Avenue, Harwell Oxford, Didcot, Oxfordshire, OX11 0QR, UK. Pavel.Matou 2: IntertekMSG, The Wilton Centre, Wilton, Redcar, TS10 4RF, UK 3: WestCHEM, Department of Pure and Applied Chemistry and CPACT, University of Strathclyde, Glasgow G1 1XL, Scotland 4: Light Systems Ltd, The Electron Building, Fermi Avenue, Harwell Oxford, Didcot, Oxfordshire, OX11 0QR, UK
Publication date: 2011-07-01
- The Society publishes the internationally recognized, peer reviewed journal, Applied Spectroscopy, which is available both in print and online. Subscriptions are included with membership or can be purchased by institutional or corporate organizations. Abstracts may be viewed free of charge. Previously published as Bulletin (Society for Applied Spectroscopy)
- Editorial Board
- Information for Authors
- Submit a Paper
- Subscribe to this Title
- Membership Information
- Request copyrighted SAS materials
- Spectroscopic Nomenclature
- Focus Compendium
- ingentaconnect is not responsible for the content or availability of external websites
- In this: publication
- By this: publisher
- In this Subject: Analytical Chemistry
- By this author: Matousek, Pavel ; Everall, Neil ; Littlejohn, David ; Nordon, Alison ; Bloomfield, Matthew

Shopping cart
Receive new issue alert
Get Permissions