Measurement of Spatial Resolution and Sensitivity in Transmission and Backscattering Raman Spectroscopy of Opaque Samples: Impact on Pharmaceutical Quality Control and Raman Tomography

$29.00 plus tax (Refund Policy)

Buy Article:

Abstract:

A practical methodology is described that allows measurement of spatial resolution and sensitivity of Raman spectroscopy in backscatter and transmission modes under conditions where photon migration dominates, i.e., with turbid or opaque samples. For the first time under such conditions the width and intensity of the point spread function (PSF) has been accurately measured as a function of sample thickness and depth below the surface. In transmission mode, the lateral resolution for objects in the bulk degraded linearly with sample thickness, but the resolution was much better for objects near either surface, being determined by the diameter of the probe beam and collection aperture irrespective of sample thickness. In other words, buried objects appear to be larger than ones near either surface. The absolute transmitted signal decreased significantly with sample thickness, but objects in the bulk yielded higher signals than those at either surface. In transmission, materials are sampled preferentially in the bulk, which has ramifications for quantitative analysis. In backscattering mode, objects near the probed surface were detected much more effectively than in the bulk, and the resolution worsened linearly with depth below the surface. These results are highly relevant in circumstances in which one is trying to detect or image buried objects in opaque media, for example Raman tomography of biological tissues or compositional and structural analysis of pharmaceutical tablets. Finally, the observations were in good agreement with Monte Carlo simulations and, provided one is in the diffusion regime, were insensitive to the choice of transport length, which shows that a simple model can be used to predict instrument performance for a given excitation and collection geometry.

Keywords: PHARMACEUTICAL; PHOTON MIGRATION; RAMAN SPECTROSCOPY; REFLECTION; SPATIAL RESOLUTION; TOMOGRAPHY; TRANSMISSION

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/000370210791211646

Affiliations: 1: Intertek-MSG, The Wilton Centre, Wilton, Redcar, TS10 4RF, UK 2: Clairet Scientific Ltd, 17/18 Scirocco Close, Moulton Park Industrial Estate, Northampton, N3 6AP, UK 3: Kaiser Optical Systems, 371 Parkland Plaza, Ann Arbor, Michigan 48103 4: School of Chemistry, University of Nottingham, University Park, Nottingham, NG7 2RD, UK

Publication date: May 1, 2010

More about this publication?
Related content

Tools

Favourites

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more