Skip to main content

Signal-to-Noise Contribution of Principal Component Loads in Reconstructed Near-Infrared Raman Tissue Spectra

Buy Article:

$29.00 plus tax (Refund Policy)

Abstract:

The overall quality of Raman spectra in the near-infrared region, where biological samples are often studied, has benefited from various improvements to optical instrumentation over the past decade. However, obtaining ample spectral quality for analysis is still challenging due to device requirements and short integration times required for (in vivo) clinical applications of Raman spectroscopy. Multivariate analytical methods, such as principal component analysis (PCA) and linear discriminant analysis (LDA), are routinely applied to Raman spectral datasets to develop classification models. Data compression is necessary prior to discriminant analysis to prevent or decrease the degree of over-fitting. The logical threshold for the selection of principal components (PCs) to be used in discriminant analysis is likely to be at a point before the PCs begin to introduce equivalent signal and noise and, hence, include no additional value. Assessment of the signal-to-noise ratio (SNR) at a certain peak or over a specific spectral region will depend on the sample measured. Therefore, the mean SNR over the whole spectral region (SNRmsr) is determined in the original spectrum as well as for spectra reconstructed from an increasing number of principal components. This paper introduces a method of assessing the influence of signal and noise from individual PC loads and indicates a method of selection of PCs for LDA. To evaluate this method, two data sets with different SNRs were used. The sets were obtained with the same Raman system and the same measurement parameters on bladder tissue collected during white light cystoscopy (set A) and fluorescence-guided cystoscopy (set B). This method shows that the mean SNR over the spectral range in the original Raman spectra of these two data sets is related to the signal and noise contribution of principal component loads. The difference in mean SNR over the spectral range can also be appreciated since fewer principal components can reliably be used in the low SNR data set (set B) compared to the high SNR data set (set A). Despite the fact that no definitive threshold could be found, this method may help to determine the cutoff for the number of principal components used in discriminant analysis. Future analysis of a selection of spectral databases using this technique will allow optimum thresholds to be selected for different applications and spectral data quality levels.

Keywords: BLADDER; PCA; PRINCIPAL COMPONENT ANALYSIS; RAMAN SPECTROSCOPY; SIGNAL-TO-NOISE RATIO; SNR

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/000370210790572052

Affiliations: 1: Dept. of Urology, University Medical Centre Utrecht, the Netherlands; Dept. of Medical Technology and Clinical Physics, University Medical Centre, Utrecht, The Netherlands 2: Dept. of Medical Physics, St Antonius Hospital, Nieuwegein, The Netherlands 3: Biophotonics Research Unit, Gloucestershire Hospitals NHS Foundation Trust, Gloucester, United Kingdom 4: Dept. of Medical Technology and Clinical Physics, University Medical Centre, Utrecht, The Netherlands 5: Dept. of Urology, University Medical Centre Utrecht, the Netherlands

Publication date: January 1, 2010

More about this publication?
sas/sas/2010/00000064/00000001/art00008
dcterms_title,dcterms_description,pub_keyword
6
5
20
40
5

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more