If you are experiencing problems downloading PDF or HTML fulltext, our helpdesk recommend clearing your browser cache and trying again. If you need help in clearing your cache, please click here . Still need help? Email help@ingentaconnect.com

Photophysics of 9,10-Anthracenediol and a Bifunctional Sacrificial Template in Solution and Xerogels

$29.00 plus tax (Refund Policy)

Buy Article:

Abstract:

Site selectively templated and tagged xerogels (SSTTX) represent a new sensing platform. Although this platform has several attractive features, the template formation process is not fully understood. To address this issue we have explored the photophysics of two model compounds (9,10-anthracenediol and a bifunctional sacrificial template (BST)) when dissolved in solution and when sequestered within a xerogel. The solution experiments show that the carbamate tethers on the BST (which are eventually cleaved to form the analyte responsive sites that make up the SSTTX) do not alter the anthracene residue's intrinsic photophysics. In contrast, 9,10-anthracenediol and BST molecules sequestered within a xerogel sense and report from a distribution of microenvironments. The distribution mean values are very similar, but the variance is statistically greater for the BST-doped xerogel in comparison to the 9,10-anthracenediol-doped xerogel. The most likely causes of this behavior are heterogeneity and electron and energy transfer processes that are controlled by differences in the position/orientation of the anthracene moiety at the pore surface in the Class I (9,10-anthracenediol) and Class II (BST) xerogels. These results also suggest that the initial template sites produced during the SSTTX formation process are not discrete; they are intrinsically more diverse (maybe 30%) in comparison to the types of template sites created by traditional molecular imprinting strategies. However, our previously reported SSTTX binding studies do not reveal any evidence for a distribution of analyte-to-SSTTX binding. This apparently anomalous behavior may result because the relative standard deviation of the binding process is intrinsically small and/or one or more of the steps that follow template site formation attenuate the final template site distribution within the SSTTX.

Keywords: FLUORESCENCE; HETEROGENEITY; MOLECULAR IMPRINTING; XEROGELS

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/000370208784046740

Affiliations: Department of Chemistry, Natural Sciences Complex, University at Buffalo, The State University of New York, Buffalo, New York 14260-3000

Publication date: April 1, 2008

More about this publication?
Related content

Tools

Favourites

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more