If you are experiencing problems downloading PDF or HTML fulltext, our helpdesk recommend clearing your browser cache and trying again. If you need help in clearing your cache, please click here . Still need help? Email help@ingentaconnect.com

Novel, Fourier Filtering Method that Reuses Interference-Patterned Spectra to Extend the Calibration Set for Thickness Determination

$29.00 plus tax (Refund Policy)

Buy Article:

Abstract:

Determining the thickness of plastic sheets on the basis of near-infrared spectra by building a multivariate calibration model requires a relatively large sample set. In the thickness region, where just a few non-interference-patterned samples are available, it is a waste of information if interference-patterned spectra are excluded. After eliminating the interference pattern from the spectra (filtering), the calibration set can be extended with these filtered spectra. Fourier transformation of an interference-patterned spectrum versus wavenumber leads to a Fourier spectrum as a function of the optical path length containing an easily recognizable interference peak. Unfortunately, this peak coincides with components of the spectral information of absorbance, on which multivariate calibration is based. Hence, replacing the interference peak is a cardinal step of the filtering process. Since the Fourier spectrum versus optical path length function is not known, it has been shown that interpolated data over the remaining Fourier components can be substituted for the missing part of the spectrum. In this paper, a novel method is proposed that uses a linear approximation between the Fourier spectra and the thickness values so that the regression coefficients are calculated on components of all but the interference-patterned Fourier spectra and the corresponding thicknesses, and then the deleted components in the filtered spectrum are replaced. This latter method yields more detailed Fourier spectra. Reducing the disturbing effect of scattering is also discussed. The effectiveness of the filtering was tested on low-density polyethylene sheets. The performance of different calibration models with or without filtering was compared by significance tests on standard error of prediction values. Application of the new Fourier type filtering technique led to significant improvements in the calibration performance.

Keywords: FOURIER FILTERING; MULTIVARIATE CALIBRATION; NEAR-INFRARED SPECTROSCOPY; NIR; PLASTIC SHEETS; THICKNESS DETERMINATION

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/000370206776023403

Affiliations: Department of Atomic Physics, Budapest University of Technology and Economics, Budafoki 8, H-1111 Budapest, Hungary

Publication date: February 1, 2006

More about this publication?
Related content

Tools

Favourites

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more