Determination of Glucose in Human Aqueous Humor Using Raman Spectroscopy and Designed-Solution Calibration

Authors: Pelletier, Christine C.1; Lambert, James L.1; Borchert, Mark2

Source: Applied Spectroscopy, Volume 59, Issue 8, Pages 166A-194A and 965-1074 (August 2005) , pp. 1024-1031(8)

Publisher: Society for Applied Spectroscopy

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Glucose concentrations of in vitro human aqueous humor (HAH) samples from cataract patients were determined using 785 nm Raman spectra and partial least squares (PLS) calibration. PLS models were created from spectra of prepared calibration solutions rather than aqueous humor samples. Spectra were obtained with an excitation energy (100 mW for 150 s), which was higher than can be applied in vivo, to decrease the models' contribution to prediction uncertainty. The solutions contained experimentally designed levels of glucose, bicarbonate, lactate, urea, and ascorbate. Multiplicative signal correction of spectra helped compensate for the ±20% drift in laser power observed at the sample over six noncontiguous days of data collection. Seventeen HAH samples containing 38-775 mg/dL of glucose exhibited a root-mean-square error (RMSEP) of 22 mg/dL, coefficient of determination (r2) of 0.989, and bias of 6 mg/dL when predicted from lower energy (30 s) spectra collected contemporaneously with fifty calibration spectra. Similar results were obtained even when spectral data were gathered separately for human aqueous humor samples and calibration samples: 10 HAH samples, calibrated on 25 solutions measured 3.6 weeks earlier, exhibited an RMSEP of 23 mg/dL, r2 of 0.992, and bias of 9 mg/dL. The results demonstrate progress toward the determination of glucose levels in patient-derived aqueous humor using laboratory-derived "artificial aqueous humor" calibration solutions.

Keywords: RAMAN; PARTIAL LEAST SQUARES; PLS; MULTIVARIATE; CALIBRATION; MULTIPLICATIVE SIGNAL CORRECTION; MSC; QUANTITATIVE; GLUCOSE; AQUEOUS HUMOR

Document Type: Research article

DOI: 10.1366/0003702054615133

Affiliations: 1: Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109 2: Division of Ophthalmology, Childrens Hospital Los Angeles and Department of Ophthalmology, Keck School of Medicine, University of Southern California, Los Angeles, California 90027

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$29.00 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A