Abstract:

All quantitative data evaluation techniques applied to spectroscopy are based on the assumption that the baseline is stable in time. If this prerequisite is violated, major concentration errors can result since drifts are evaluated along with true spectroscopic features. For handling baseline drifts two improved principal component regression (PCR) methods are presented and compared to conventional Savitzky–Golay preprocessing followed by conventional PCR. The proposed drift-correction methods take advantage of baseline drifts being rather broad compared to the absorption features. The only assumption made is that drift effects can be modeled sufficiently by polynomials of user-selectable order. One correction method modifies principal components such that drifts of polynomial shape are orthogonal to the calibration model and thus cannot influence the concentration result. The second method extends the calibration model by synthetic so-called pseudo-principal components. While the principal components model the true spectral features, the pseudo-principal components describe drifts simultaneously and independently. Hence, drifts are explicitly included into the calibration and cannot cause erroneous concentration results. It is demonstrated that both correction methods are equivalently as powerful as the conventional PCR in the absence of drifts and superior if drifts are present. The overall performance—in the absence and presence of baseline drifts—of the novel methods makes them more versatile and reliable than the conventional Savitzky–Golay data preprocessing. In almost all investigated cases, the average concentration errors were significantly smaller than those obtained by Savitzky–Golay preprocessing. Furthermore, polyPCR and pPCR do not need laborious optimizations as Savitzky–Golay does for preventing suppression of relevant signal components. polyPCR demands less computation expense than Savitzky–Golay, and pPCR extracts the drift spectrum as additional qualitative information not provided by Savitzky–Golay.

Keywords: Attenuated total reflection spectroscopy; Baseline drift correction; Calibration model extension; Golay; Optical spectra; PCR; Principal component regression; Savitzky&ndash

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/000370204873051

Affiliations: 1: Arizona State University, Department of Chemistry and Biochemistry, Mail stop 1604, Tempe, Arizona 85287 2: ViennaUniversity of Technology, Institute for Chemical Technology and Analytics, Getreidemarkt 9/164, A-1060 Vienna, Austria 3: Georgia Institute of Technology, School of Chemistry and Biochemistry, Atlanta, Georgia 30332-0400

Publication date: June 1, 2004

More about this publication?
sas/sas/2004/00000058/00000006/art00012
dcterms_title,dcterms_description,pub_keyword
6
5
20
40
5

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more