Skip to main content

Dual Source Fourier Transform Polarization Modulation Spectroscopy: An Improved Method for the Measurement of Circular and Linear Dichroism

Buy Article:

$29.00 plus tax (Refund Policy)

Abstract:

It is shown that the use of two sources in a four-port interferometer equipped with cube-corner mirrors leads to increased signal-tonoise ratios in Fourier transform (FT-IR) circular and linear dichroism spectra. The output beam to the sample is a superposition of two interferograms, one from each source, having opposite Fourier phases. These two interferograms cancel one another to the degree that the two sources are matched in intensity. If the radiation from each of the two sources is first polarized orthogonally with respect to the other and passed through a polarization modulator before reaching the sample, the resulting polarization-modulation interferograms are out of Fourier phase and out of polarization-modulation phase. As a result, the polarization-modulation interferograms, due to circular or linear dichroism in the sample, from the two sources combine positively rather than negatively. An improvement in signal-to-noise ratio of up to two (or a factor of four in scan-time reduction for the same signal-to-noise ratio) compared to single source operation can be realized, while at the same time, the potential for saturation of the detector signal is significantly reduced due to the reduction in magnitude of the combined ordinary infrared transmission interferogram. Absorption and circular dichroism spectra from a dual-source FT-IR spectrometer are presented and analyzed.

Keywords: Fourier transform infrared; Polarization modulation; Signal-to-noise ratio optimization; Vibrational circular dichroism; Vibrational linear dichroism

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/000370204872926

Affiliations: 1: Department of Chemistry, Syracuse University, Syracuse, New York 13244-4100; BioTools, Inc., 950 N. Rand Road, Unit 123, Wauconda, Illinois 60084 2: ABB Bomem, 585, Charest Blvd.East, Quebec (Quebec) G1K 9H4, Canada 3: Department of Chemistry, Syracuse University, Syracuse, New York 13244-4100 4: BioTools, Inc., 950 N. Rand Road, Unit 123, Wauconda, Illinois60084

Publication date: June 1, 2004

More about this publication?
sas/sas/2004/00000058/00000006/art00006
dcterms_title,dcterms_description,pub_keyword
6
5
20
40
5

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more