N2 CARS Thermometry within the Outer Jacket of a Metal Halide Lamp

$29.00 plus tax (Refund Policy)

Buy Article:

Abstract:

We applied high-resolution coherent anti-Stokes Raman spectroscopy (CARS) to measure the gas temperature at a number of points within the nitrogen-filled outer jacket of a 360 W metal halide lamp. A comparison between the measured rotationally resolved N2 CARS spectra with spectral simulations collected between 500 and 1000 K allowed the temperature at each point in the lamp to be determined. In addition to demonstrating the diagnostic power of the CARS technique in a high-intensity discharge lamp, a comparison of the measured temperatures to calculated axial and radial temperature profiles was achieved. Good agreement between the theoretical and experimental temperature profiles was attained.

Keywords: CARS; COHERENT ANTI-STOKES RAMAN SPECTROSCOPY; HIGH-INTENSITY DISCHARGE; LAMP; METAL HALIDE; NITROGEN; THERMOMETRY

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/0003702001950328

Affiliations: Research and Development, OSRAM SYLVANIA, 71 Cherry Hill Drive, Beverly, Massachusetts 01915

Publication date: June 1, 2000

More about this publication?
Related content

Tools

Favourites

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more