Evaluation of Data Pretreatment and Model Building Methods for the Determination of Glucose from Near-Infrared Single-Beam Spectra
Authors: Ding, Qing; Small, Gary W.; Arnold, Mark A.
Source: Applied Spectroscopy, Volume 53, Issue 4, Pages 144A-171A and 375-488 (April 1999) , pp. 402-414(13)
Publisher: Society for Applied Spectroscopy
Abstract:
Near-infrared single-beam spectra are used to build partial least-squares (PLS) calibration models for the determination of glucose in biological matrices. Two different data sets of the same sample constituents are used in this investigation. The glucose samples consist of an aqueous matrix of varied concentrations of bovine serum albumin (BSA) and triacetin. The BSA and triacetin are models for blood proteins and triglycerides, respectively. Due to the effects of intensity variation in the single-beam spectra, calibration models obtained with unprocessed spectra are not as good as those computed with the corresponding spectra in absorbance units. When this intensity variation is reduced through the use of multiplicative signal correction (MSC), a spectral normalization method, or a logarithmic transform, the resulting models are as good as or better than those obtained in the analysis of absorbance spectra. An attempt is made to model the nonlinear relationship between single-beam spectral intensities and glucose concentrations by use of stepwise quadratic PLS (QPLS) models. The QPLS models are found to perform better than linear PLS models in some cases (e.g., with MSC-corrected single-beam spectra). The effect of digital filtering on the calibration models computed with single-beam spectra is also studied. The results obtained with and without filtering are found to be similar in terms of model performance, but the models based on filtered single-beam intensities require fewer latent variables and perform more consistently as a group. A final test is performed to compare the robustness of calibration models computed with single-beam spectra to those based on absorbance spectra. When applied to spectra that lie outside the time span of the calibration data, the models based on single-beam spectra are still competitive with those computed with absorbance spectra.Keywords: NEAR-INFRARED; GLUCOSE; SINGLE-BEAM SPECTRA; MULTIVARIATE CALIBRATION; PARTIAL LEAST-SQUARES
Document Type: Research article
DOI: http://dx.doi.org/10.1366/0003702991946866
Publication date: 1999-04-01
- The Society publishes the internationally recognized, peer reviewed journal, Applied Spectroscopy, which is available both in print and online. Subscriptions are included with membership or can be purchased by institutional or corporate organizations. Abstracts may be viewed free of charge. Previously published as Bulletin (Society for Applied Spectroscopy)
- Editorial Board
- Information for Authors
- Submit a Paper
- Subscribe to this Title
- Membership Information
- Request copyrighted SAS materials
- Spectroscopic Nomenclature
- Focus Compendium
- ingentaconnect is not responsible for the content or availability of external websites
- In this: publication
- By this: publisher
- In this Subject: Analytical Chemistry
- By this author: Ding, Qing ; Small, Gary W. ; Arnold, Mark A.

Shopping cart
Receive new issue alert
Get Permissions