Surface-Enhanced Raman Detection of Aqueous Cyanide

$29.00 plus tax (Refund Policy)

Buy Article:

Abstract:

Cyanide ion (CN-) has been the subject of numerous studies probing the mechanisms underlying the surface-enhanced Raman scattering (SERS) phenomenon. This work examines various aspects critical to application of SERS for direct detection of trace cyanide in groundwater and in wastewater streams. A new method for direct quantitation of cyanide in aqueous electrolyte has been developed that uses an ex situ oxidation-reduction cycle to precondition a planar silver electrode. Cyanide ion can be detected in 0.1 M KCI with a linear response between 100 ppm and 10 ppb. The estimated limit of detection is approximately 8 ppb. The effects of pH, electrolyte level, and two common background ions, nitrate (NO3-) and sulfate (SO4 2-), have been characterized. Cyanide response was found to be sensitive to pH, with optimal performance observed at neutral to basic pH. Electrolyte concentrations of 0.001 M reduced response to cyanide by a factor of five, while levels above 0.1 M had no significant effect. The addition of 10-ppm sulfate ion decreased response approximately 40%, while the presence of nitrate ion at concentrations up to 100 ppm had a negligible effect on SERS response. These results suggest that cyanide ion can be detected directly in high-ionic-strength aqueous solutions, such as groundwater.

Keywords: Cyanide; Electrochemical; Groundwater; Process monitoring; SERS

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/0003702944029677

Affiliations: 1: Health Sciences Research Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, 37831-6113 2: Health Sciences Research Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, 37831-6113; current address; EIC Laboratories, Inc., Norwood, MA 02062

Publication date: August 1, 1994

More about this publication?
Related content

Tools

Favourites

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more