Compact Table for the Publication of Infrared Spectra That Are Quantitative on Both Intensity and Wavenumber Axes
Authors: Bertie, John E.; Jones, R. Norman; Apelblat, Yoram
Source: Applied Spectroscopy, Volume 47, Issue 12, Pages 1959-2177 (December 1993) , pp. 1989-2001(13)
Publisher: Society for Applied Spectroscopy
Abstract:
A Compact Table format is presented for the publication of infrared spectra that are quantitative on both intensity and wavenumber axes. The format is illustrated with a molar absorption coefficient spectrum, Em(v) vs. v and with infrared real and imaginary refractive index spectra, n vs. v and k(v) vs. v, respectively. The algorithm consists of two steps: first, the number of spectral points is reduced by using larger wavenumber spacings than appear in the original spectrum; second, the resulting spectral points are presented in a compressed table format. The Compact Table is about one tenth the size required for the original spectrum to be presented in a conventional XY table. The essential criterion for increasing the wavenumber spacing is that it must be possible to recover the original spectrum by interpolation to an accuracy better than that of the original spectrum. Nearly all the recovered imaginary refractive index and molar absorption coefficient values are within 1% of the original values, and for each quantity the average of the magnitudes of the accuracies of recovery is 0.2%. The real refractive index spectrum is most accurately recovered by Kramers-Kronig transformation of the recovered imaginary refractive index spectrum. Nearly all the recovered real refractive index values are within 0.02% of the original values, and the average of the magnitudes of the accuracies of recovery is 0.005%. The real and imaginary infrared dielectric constant spectra, ε′(v) vs. v and ε″(v) vs. v, can be calculated from the recovered data with an accuracy in ε′ that is about one half of that of the real refractive index and an accuracy in ε″ that is approximately that of the imaginary refractive index. The detailed method is outlined and is applied to infrared intensities of chlorobenzene. Computer programs are presented for the construction of the Compact Table and for the recovery of the full spectrum from the tabulated information.Keywords: Infrared; Infrared intensities; Spectroscopic techniques
Document Type: Research article
DOI: http://dx.doi.org/10.1366/0003702934066497
Affiliations: 1: Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada
Publication date: 1993-12-01
- The Society publishes the internationally recognized, peer reviewed journal, Applied Spectroscopy, which is available both in print and online. Subscriptions are included with membership or can be purchased by institutional or corporate organizations. Abstracts may be viewed free of charge. Previously published as Bulletin (Society for Applied Spectroscopy)
- Editorial Board
- Information for Authors
- Submit a Paper
- Subscribe to this Title
- Membership Information
- Request copyrighted SAS materials
- Spectroscopic Nomenclature
- Focus Compendium
- ingentaconnect is not responsible for the content or availability of external websites
- In this: publication
- By this: publisher
- In this Subject: Analytical Chemistry
- By this author: Bertie, John E. ; Jones, R. Norman ; Apelblat, Yoram

Shopping cart
Receive new issue alert
Get Permissions