FT-Raman on-Line Analysis of PCI3 Reactor Material

$29.00 plus tax (Refund Policy)

Buy Article:

Abstract:

Fourier transform (FT)-Raman spectroscopy has been applied to the online analysis and control of a PCI3 reactor. This particular analytical technique was selected from a consideration of the Raman scattering efficiencies of the constituents of the reaction and the ability of the fiberoptic-coupled, near-IR, FT-Raman systems to remotely sample the toxic and potentially hazardous reaction mixture. In this communication we describe the Raman spectra of P4, PCl3, PCl5, and P4 dissolved in PCl3, as well as related compounds, along with relative band intensities of the constituents of the reaction. Factors leading to the optimum FT-Raman configuration for this particular process control problem are discussed in detail.

Keywords: Analytical methods; Raman spectroscopy; Spectroscopic techniques

Document Type: Research Article

DOI: http://dx.doi.org/10.1366/0003702934068026

Affiliations: 1: Monsanto Corporate Research, 700 Chesterfield Parkway North, St. Louis, Missouri 63198 2: The Chemical Group, Monsanto Company, 800 North Lindbergh Boulevard, St. Louis, Missouri 63167