Abstract:

Recently much work has been done on Chinese porcelains with the use of the EDXRF technique; the results have been encouraging. In general, quantitative elemental determination requires tedious calibration procedures. In this study, we shall use a simplified, rapid EDXRF method to obtain quantitative values of trace elements of rubidium, strontium, yttrium, zirconium, and niobium. Briefly, the method makes use of the calibration curve on a plot of ln[intensity (cps)/concentration (%)] vs. ln[energy (keV)] for the elements Rb to Nb. Using such a calibration curve, we were able to obtain quantitative values of the concentration of the element by simply measuring its intensity under the same geometrical conditions.

Keywords: X-ray fluorescence

Document Type: Short Communication

DOI: http://dx.doi.org/10.1366/0003702874447293

Affiliations: Department of Physics, National University of Singapore, Singapore 0511

Publication date: November 1, 1987