Transient identification of defective trap seals

$54.78 plus tax (Refund Policy)

Buy Article:

Abstract:

The prevention of the ingress of contaminated air into habitable spaces has been a central concern in the design of building drainage and vent systems since the 1850s. Failure to provide the necessary protection, primarily through appliance water trap seals, was shown to have been a significant contributor to the Severe Acute Respiratory Syndrome (SARS) epidemic spread in Hong Kong, China, in 2003. Prevention depends upon both good design, to limit the air pressure transients propagated within the system, and good maintenance. Good practice has evolved to include wherever practical long radius bends to minimize the local air pressure changes. Similarly, modern usage of drainage networks includes the random discharge of disposable sanitary and hygiene products that may interact with undesirable rapid changes in flow direction and thereby contribute to local surcharge conditions. However, a maintenance regime within a large complex building network also requires a degree of prior knowledge of possible defective appliance trap seal locations. This paper proposes the use of air pressure transient simulation and transient response measurement to identify, during periods of system non-use, the location of depleted trap seals. The simulation of air pressure transient propagation within building drainage and vent systems is detailed, based on the proven capabilities of the method of characteristics solution of the St Venant equations. Validation of system transient response simulation is presented together with indications of the impact of a defective appliance trap seal on the system response to an applied low-amplitude, short-duration, pressure surge. Comparison of the defect free and defective system response is shown to be sufficiently discriminatory to allow the identification of an appliance trap seal in need of replenishment. Identification of persistent trap seal depletion would allow local installation of active control devices to prevent further failures – including the addition of either air admittance valves to limit trap seal loss to negative transients or variable volume containment positive air pressure attenuators to limit trap seal loss due to positive pressure transients.

Keywords: building operation; building services; defects identification; disease vectors; drainage design; drainage systems; public health; water seals; water traps

Document Type: Research Article

DOI: http://dx.doi.org/10.1080/09613210500094219

Affiliations: Drainage Research Group, School of the Built Environment, Heriot Watt University, Edinburgh, EH14 4AS, UK

Publication date: May 1, 2005

More about this publication?
Related content

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more