Comparison of Cozart® Microplate ELISA and GC–MS Detection of Methadone and Metabolites in Human Hair
Authors: Cooper, Gail1; Wilson, Lisa1; Reid, Claire1; Baldwin, Dene1; Hand, Chris1; Spiehler, Vina2
Source: Journal of Analytical Toxicology, Volume 29, Number 7, October 2005 , pp. 678-681(4)
Publisher: Preston Publications
Abstract:
The purpose of this study was to determine the performance characteristics of the Cozart Methadone Microplate ELISA assay for the detection of methadone and methadone metabolites in hair specimens. One hundred and ten hair specimens were collected from volunteers (n = 46) with a history of drug use and from drug-related deaths (n = 64). The hair samples (approximately 20 mg) were extracted by sonication in methanol followed by overnight extraction in methanol at 60°C. The methanol extract was evaporated to dryness, reconstituted in ELISA negative calibrator, and then analyzed. For gas chromatography–mass spectrometry (GC–MS) analysis, deuterated internal standard mixture [methadone-d9 and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP)-d3] and 0.1M HCl were added to approximately 20 mg of specimen or spiked blank hair and sonicated for 1 h. The pH was adjusted to neutral, and methadone and its primary metabolite, EDDP, were analyzed by GC–MS following solid-phase extraction using Bond Elute Certify columns and pH 7.4 phosphate buffer (0.1M). Forty hair specimens were confirmed positive for methadone by GC–MS. Concentrations ranged from 0.10 to 8.3 ng/mg for methadone and 0.1 to 1.2 ng/mg for EDDP. The true positives, true negatives, false positives, and false negatives for different cutoffs with the ELISA were determined by comparison of the ELISA response (normalized to weight of hair extracted) to the GC–MS results with a cutoff of 0.1 ng/mg for both methadone and EDDP as the reference method. The optimum cutoff for the Cozart Methadone Microplate ELISA was determined to be between 200 and 300 pg methadone equivalents/mg hair using a 20 mg hair sample. The Cozart Methadone Microplate EIA for methadone and metabolites in hair using a cut-off of 200 pg/mg hair with a 20 mg hair sample had a sensitivity of 95 ± 2% and a specificity of 100 ± 3.5% (vs GC–MS) and an accuracy of 98.2 ± 1.3%.Document Type: Research article
Affiliations: 1: Cozart Bioscience Ltd, Abingdon, Oxfordshire OX14 4RY, U.K. 2: Spiehler and Associates, Newport Beach, California 92663
Publication date: 2005-10-01
The Journal of Analytical Toxicology (JAT), established in 1977 and published 9 times a year, is the international source covering a broad range of clinical, forensic, and industrial laboratory topics regarding the isolation, identification, and quantitation of potentially toxic substances.
With an emphasis on practical application, JAT articles provide improved and novel techniques for use in clinical, forensic, workplace, sports testing (doping), and other toxicology laboratories. Articles describe newly developed methods in immunoassay testing, gas chromatography, liquid chromatography, mass spectrometry, atomic absorption spectrometry, solid and liquid phase extraction techniques, and other analytical approaches. Worldwide readership includes toxicologists, pathologists, chemists, clinicians, researchers, and educators working in medical examiner and law enforcement laboratories, hospitals, university and independent analytical laboratories, as well as the drug manufacturing industry.
Each year in October, we publish a special issue from the Society of Forensic Toxicologists.
JAT, as determined by ISI Citation Index, is one of the two most referenced international journals in forensic science.
- Subscribe to this Title
- ingentaconnect is not responsible for the content or availability of external websites
- In this: publication
- By this: publisher
- In this Subject: Ecology , Toxicology
- By this author: Cooper, Gail ; Wilson, Lisa ; Reid, Claire ; Baldwin, Dene ; Hand, Chris ; Spiehler, Vina

Shopping cart
Receive new issue alert
Get Permissions