Comparison of Cozart® Microplate ELISA and GC–MS Detection of Methadone and Metabolites in Human Hair

Authors: Cooper, Gail1; Wilson, Lisa1; Reid, Claire1; Baldwin, Dene1; Hand, Chris1; Spiehler, Vina2

Source: Journal of Analytical Toxicology, Volume 29, Number 7, October 2005 , pp. 678-681(4)

Publisher: Preston Publications

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

The purpose of this study was to determine the performance characteristics of the Cozart Methadone Microplate ELISA assay for the detection of methadone and methadone metabolites in hair specimens. One hundred and ten hair specimens were collected from volunteers (n = 46) with a history of drug use and from drug-related deaths (n = 64). The hair samples (approximately 20 mg) were extracted by sonication in methanol followed by overnight extraction in methanol at 60°C. The methanol extract was evaporated to dryness, reconstituted in ELISA negative calibrator, and then analyzed. For gas chromatography–mass spectrometry (GC–MS) analysis, deuterated internal standard mixture [methadone-d9 and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP)-d3] and 0.1M HCl were added to approximately 20 mg of specimen or spiked blank hair and sonicated for 1 h. The pH was adjusted to neutral, and methadone and its primary metabolite, EDDP, were analyzed by GC–MS following solid-phase extraction using Bond Elute Certify columns and pH 7.4 phosphate buffer (0.1M). Forty hair specimens were confirmed positive for methadone by GC–MS. Concentrations ranged from 0.10 to 8.3 ng/mg for methadone and 0.1 to 1.2 ng/mg for EDDP. The true positives, true negatives, false positives, and false negatives for different cutoffs with the ELISA were determined by comparison of the ELISA response (normalized to weight of hair extracted) to the GC–MS results with a cutoff of 0.1 ng/mg for both methadone and EDDP as the reference method. The optimum cutoff for the Cozart Methadone Microplate ELISA was determined to be between 200 and 300 pg methadone equivalents/mg hair using a 20 mg hair sample. The Cozart Methadone Microplate EIA for methadone and metabolites in hair using a cut-off of 200 pg/mg hair with a 20 mg hair sample had a sensitivity of 95 ± 2% and a specificity of 100 ± 3.5% (vs GC–MS) and an accuracy of 98.2 ± 1.3%.

Document Type: Research article

Affiliations: 1: Cozart Bioscience Ltd, Abingdon, Oxfordshire OX14 4RY, U.K. 2: Spiehler and Associates, Newport Beach, California 92663

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$43.00 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A