Entropy indices vs the bispectral index™ for estimating nociception during sevoflurane anaesthesia

Authors: Takamatsu, I.; Ozaki, M.; Kazama, T.

Source: BJA: British Journal of Anaesthesia, Volume 96, Number 5, May 2006 , pp. 620-626(7)

Publisher: Oxford University Press

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Background. It is now possible to acquire and process raw EEG and frontal EMG signals to produce two spectral-entropy-based indices (response entropy and state entropy) reflective of analgesic and hypnotic levels during general anaesthesia (with the Datex-Ohmeda S/5 Entropy Module, Datex-Ohmeda, Helsinki, Finland). However, there are no data available on the accuracy of the Entropy Module in estimating nociception during sevoflurane anaesthesia.

Methods. Forty female patients were enrolled in the present study. Each patient was allocated randomly to one of four end-tidal sevoflurane concentration (ET<inf>sev</inf>) groups (1.3, 1.7, 2.1 or 2.5%). A BIS Sensor™ (Aspect Medical Systems, Newton, MA) and an Entropy Sensor™ (Datex-Ohmeda) were applied side-by-side to the forehead. The bispectral index (A-2000 BIS Monitor, version 3.4, Aspect Medical Systems), response entropy, state entropy and patient movement were observed after electrical stimulation (20, 40, 60 and 80 mA, 100 Hz, 5 s) and after skin incision during sevoflurane anaesthesia (1.3, 1.7, 2.1 or 2.5%). Accuracy of the EEG variables in differentiating the intensity of electrical stimulation was estimated by the prediction probability (P<inf>K</inf>) values.

Results. Response entropy and state entropy [median, (range)] before skin incision were significantly lower in patients who did not move [29 (15–41) and 24 (14–41)] than in those that did [38 (24–53) and 37 (24–52)], but there was no significant difference in BIS. All EEG variables increased significantly (P<0.0001 for all) with increases in the intensity of electrical stimulation. The difference between response entropy and state entropy increased with increases in the electrical stimulation (P<0.0001). However, no EEG variables could differentiate the intensity of the electrical stimulations accurately because of low P<inf>K</inf>-values (P<inf>K</inf><0.8).

Conclusion. Noxious stimulation increased the difference between response entropy and state entropy. However, an increase in the difference does not always indicate inadequate analgesia and should be interpreted carefully during anaesthesia.

Keywords: anaesthetics volatile, sevoflurane; measurement techniques, spectral analysis; monitoring, bispectral index; potency, analgesic

Document Type: Research article

DOI: 10.1093/bja/ael050

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$40.19 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A