Randomized comparison of three methods of induction of anaesthesia with sevoflurane<cross-ref refid="fn1" type="fn"></cross-ref>

Authors: Knaggs, C. L.1; Drummond, G. B.2

Source: BJA: British Journal of Anaesthesia, Volume 95, Number 2, August 2005 , pp. 178-182(5)

Publisher: Oxford University Press

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Background. Rebreathing will occur if a low gas flow and a Mapleson D circuit are used to induce anaesthesia with a volatile anaesthetic agent. This has the advantage that it allows ventilation to be sustained when consciousness is lost, and specific manoeuvres such as breath-holding or vital capacity breaths are not needed to facilitate induction of anaesthesia. However, if the fresh gas flow were too small, this would slow induction by limiting the rate of delivery of the anaesthetic agent. To assess the impact of fresh gas flow and rebreathing, we compared induction using sevoflurane 8% given by three different methods.

Methods. We randomly allocated 65 patients to receive induction of anaesthesia from either a Mapleson A breathing system with a fresh gas flow of 9 litre min-1 (group A9), a Mapleson D system with a fresh flow of 6 litre min-1 (group D6) or a Mapleson D system with a fresh flow of 3 litre min-1 (group D3). We measured times for induction, end-tidal sevoflurane and end-tidal carbon dioxide.

Results. The median (quartiles) induction times were 58 (45, 72), 50 (42, 65) and 64 (52, 92) s in the groups A9, D6 and D3 respectively. Induction of anaesthesia took longer (P<0.01) and was more variable in group D3. In this group, end-tidal sevoflurane concentration at the time of induction of anaesthesia was lower (P<0.05). In group A9, end-tidal carbon dioxide was less (P<0.05).

Conclusions. In adult patients allowed to breathe normally, prompt and consistent inhalation induction of anaesthesia with sevoflurane is obtained when fresh gas flow is limited to 6 litre min-1 from a Mapleson D circuit, but smaller flows are impractical.

Keywords: anaesthesia; induction; inhalation; breathing system; Mapleson; carbon dioxide; rebreathing

Document Type: Research article

DOI: 10.1093/bja/aei149

Affiliations: 1: Clinical Neurosciences and 2: Department of Anaesthesia, Critical Care, and Pain Medicine, Royal Infirmary, Edinburgh EH16 4SA, UK

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$40.03 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A