Use of an electronic nose for detection of biofilms

Authors: Thaler, Erica R.1; Huang, Dan2; Giebeig, Lisa3; Palmer, James1; Lee, Dan2; Hanson, C. William3; Cohen, Noam1

Source: American Journal of Rhinology, Volume 22, Number 1, January-February 2008 , pp. 29-33(5)

Publisher: OceanSide Publications, Inc

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Background: Prior work has indicated that electronic nose (enose) technology can distinguish among bacteria samples and identify patients with ventilator-associated pneumonia and rhinosinusitis. This study was performed to test the hypothesis that an enose can distinguish between biofilm-producing and non-biofilm-producing bacteria of the same species.

Methods: Biofilm-producing and non-biofilm-producing mutant strains of Pseudomonas (PA01 and Sad36) and Staphylococcus (Staph WT and Staph SrtA−B−) were incubated and then sampled by the enose. Data were evaluated by logistic regression to perform binary classification of the bacteria. Training sets and testing sets were developed in two ways: by cross-validation with a leave-1-day-out method, and then by testing the last 4 days versus the first 18 days.

Results: By the leave-1-day-out method, logistic regression analysis of 198 samples of each bacterium determined that the training accuracy of the enose for both Pseudomonas species was 100% and the testing accuracy was 91.4% for PA01 and 88.4% for Sad36. The training accuracy of the enose for Staphylococcus species was 87.1% for Staph SrtA−B− and 88.2% for Staph WT and the testing accuracy was, respectively, 75.3 and 76.8%. By separating the first 18 days from the last 4 days, logistic regression analysis determined that the training accuracy of the enose for both Pseudomonas species was 100% and the testing accuracy was 100% for PA01 and 80.6% for Sad36. The training accuracy of the enose for Staphylococcus species was 87.7% for Staph SrtA−B− and 86.4% for Staph WT and the testing accuracy was respectively, 72.2 and 91.7%.

Conclusion: The enose was able to identify correctly biofilm- versus non-biofilm-producing Pseudomonas and Staphylococcus species with accuracy ranging from 72.2 to 100%, depending on the particular organism and the data analysis methodology. These results suggest that biofilms may be an in vivo marker, which the enose can use to identify patients with particularly virulent and medically recalcitrant forms of chronic rhinosinusitis.

Keywords: Biofilms; chronic sinusitis; electronic nose; infection; logistic regression; Pseudomonas; Staphylococcus

Document Type: Research article

DOI: 10.2500/ajr.2008.22.3126

Affiliations: 1: From the Department of Otorhinolaryngology Head and Neck Surgery, 2: School of Engineering, and 3: Department of Anesthesiology, Critical Care Medicine, University of Pennsylvania, Philadelphia, Pennsylvania

* This feature is in beta and some links may initially be displayed as numbers instead of article titles. Clicking on any of the links will take you to the recommended articles, regardless of the display of the link.

The full text article is available for purchase

$25.00 plus tax

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A