Compressive biomechanical properties of human nasal septal cartilage

Authors: Richmon, Jeremy D.; Sage, August; Wong, Van W.; Chen, Albert C.; Sah, Robert L.; Watson, Deborah

Source: American Journal of Rhinology, Volume 20, Number 5, September-October 2006 , pp. 496-501(6)

Publisher: OceanSide Publications, Inc

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Background: Nasal septal cartilage is frequently used in nasal reconstruction and is a common source of chondrocytes for cartilage tissue engineering. The biomechanical properties of septal cartilage have yet to be fully defined and this limits the ability to compare it to the various alternative tissue-implant materials or tissue-engineered neocartilage. Given the unique structure and orientation of the septum within the nose, we sought to investigate anisotropic behaviors of septal cartilage in compression and correlate this to the concentration of glycosaminoglycans (GAG) and collagen within the cartilage.

Methods: Human nasal septal cartilage specimens were tested in confined compression, with each sample analyzed in a medial orientation and also either a vertical or caudal-cephalic orientation, with the order of tests randomized. The equilibrium confined compression (aggregate) modulus, HA0, and the permeability, kp, at different offset compression levels were obtained for each compression test. After testing, the cartilage samples were solubilized, and the concentrations of GAG and collagen were obtained.

Results: Forty-nine compression tests (24 medial, 12 vertical, 13 caudal-cephalic) were run on cartilage specimens obtained from 21 patients. There was a significant effect of orientation on compression modulus, HA0, with the vertical (0.7 ± 0.12 MPa) and caudal-cephalic (0.66 ± 0.01 MPa) orientations being significantly stiffer (p = 0.05) than the medial orientation (0.44 ± 0.04 MPa). There was a trend of an orientation effect on kp at 15% offset compression (p = 0.12) and a borderline significant effect of orientation on kp at 30% offset compression (p = 0.05), demonstrating the M orientation to be more permeable than both the vertical and caudal-cephalic orientations. Both univariate and multivariate analysis did not demonstrate a significant effect of order of compression, age, gender, thickness, dry/wet weight, GAG, or collagen on either HA0, or kp values (p > 0.05).

Conclusion: This study provides new information on the compressive properties of septal cartilage along different axes of compression. The results demonstrate that human septal cartilage is anisotropic; the compressive stiffness is higher in the vertical and caudal-cephalic orientations than in the medial orientation. Additionally, the medial orientation tends to have the greatest permeability. The data obtained in this study provide a reference to which various craniofacial reconstruction materials and tissue-engineered neocartilage can be compared.

Document Type: Research article

DOI: 10.2500/ajr.2006.20.2932

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$49.50 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A