Open Access Comparative Effectiveness of an Adjustable Transfemoral Prosthetic Interface Accommodating Volume Fluctuation: Case Study

Download Article:
 Download
(PDF 579.927734375 kb)
 
The socket-limb interface is vital for functionality and provides stability and mobility for the amputee. Volume fluctuation can lead to compromised fit and function. Current socket technology does not accommodate for volume fluctuation. An adjustable interface may improve function and comfort by filling this technology gap. The purpose of this study was to compare the effectiveness of the standard of care (SOC) ischial ramus containment to an adjustable transfemoral prosthetic interface socket in the accommodation of volume fluctuation. A prospective experimental case study using repeated measures of subjective and performance outcome measures between socket conditions was employed. In the baseline volume condition, the adjustable socket improved subjective and performance measures 19% to 37% over SOC, whereas the two-minute walk test demonstrated equivalence. In the volume loss condition, the adjustable socket improved all subjective and performance measures 22% to 93%. All aggregated data improved 16% to 50% compared with the SOC. In simulated volume gain, the SOC socket failed, while the subject was able to complete the protocol using the adjustable socket. In this case study, the SOC socket was inferior to the comparative adjustable transfemoral amputation interface in subjective and performance outcomes. There is a lack of clinical trials and evidence comparing socket functional outcomes related to volume fluctuation.

31 References.

No Supplementary Data.
No Data/Media
No Metrics

Keywords: AMPUTEE; ISCHIAL CONTAINMENT; LIMB LOSS; LOWER EXTREMITY AMPUTEE; REHABILITATION; SOCKET

Document Type: Research Article

Publication date: 2016-09-01

More about this publication?
  • Technology and Innovation, edited and published by the National Academy of Inventors, is a forum for presenting information encompassing the entire field of applied sciences, with a focus on transformative technology and academic innovation. Regular features of T&I include commentaries contributed by the United States Patent and Trademark Office (USPTO) and in-depth profiles of Fellows of the National Academy of Inventors in every issue.

  • Access Key
  • Free content
  • Partial Free content
  • New content
  • Open access content
  • Partial Open access content
  • Subscribed content
  • Partial Subscribed content
  • Free trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more