Skip to main content

Free Content Comparability of three-dimensional optic disc imaging with different techniques: A study with confocal scanning laser tomography and raster tomography

Download Article:

The full text article is temporarily unavailable.

We apologise for the inconvenience. Please try again later.

Abstract:

ABSTRACT.Purpose:

We wanted to compare optic nerve head topography measurements and discrimination between normal and glaucomatous eyes with two entirely different three-dimensional optic disc imaging techniques, confocal scanning laser tomography (Heidelberg Retina Tomograph, Heidelberg Engineering) and raster tomography (Glaucoma-Scope, Ophthalmic Imaging Systems).

Methods:

Both eyes of 225 normal subjects and 229 eyes of 166 patients with glaucoma at different stages were imaged with the Heidelberg Retina Tomograph and the Glaucoma-Scope. Optics discs were analysed in 15° sectors around the circumference. Depth measurements were calibrated on objects with known dimensions.

Results:

We observed no significant differences in absolute measurements of maximum cup depth and cup area between the two instruments. We observed small differences in absolute measurements of disc anti rim area between the two instruments. Discrimination between normal and glaucomatous eyes was close to identical for the two instruments. Both instruments had the same ability to distinguish glaucomatous regional alterations of optic nerve head topography from normal disc configuration.

Conclusion:

Both instruments while using entirely different principles for three-dimensional optic disc imaging gave very similar results. This correspondence of results implies that the same optic disc parameters can be analysed, and the results interpreted similarly for both methods, and probably with other three-dimensional imaging instruments. It may also indicate that results of studies with one of the instruments have general validity.

Keywords: glaucoma diagnosis; optic disc topography; raster tomography; scanning laser tomography

Document Type: Editorial

Affiliations: Department of Ophthalmology, Malmö University Hospital, Malmö, Sweden

Publication date: 2000-02-01

  • Access Key
  • Free ContentFree content
  • Partial Free ContentPartial Free content
  • New ContentNew content
  • Open Access ContentOpen access content
  • Partial Open Access ContentPartial Open access content
  • Subscribed ContentSubscribed content
  • Partial Subscribed ContentPartial Subscribed content
  • Free Trial ContentFree trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more