Can Doppler time domain analysis of microembolic signals discriminate between gaseous and solid microemboli in patients with left ventricular assist device?

Authors: Thoennissen, Nils H.1; Allroggen, Achim1; Dittrich, Ralf1; Ritter, Martin1; Schmid, Christof2; Scheld, Hans H.2; Ringelstein, E. Bernd1; Nabavi, Darius G.1

Source: Neurological Research, Volume 27, Number 7, October 2005 , pp. 780-784(5)

Publisher: Maney Publishing

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Objective: Microembolic signals (MES) can be detected by transcranial Doppler sonography (TCD). To identify gaseous microemboli the inhalation of oxygen is an established method in patients with prosthetic heart valves. Time domain analysis of sample volume length (SVL) and of frequency modulation showed promising results in the discrimination between solid and gaseous microemboli. We investigated whether these time domain analyses allow the discrimination of different types of microemboli in patients with the non-pulsatile DeBakey left ventricular assist device (LVAD).

Materials and methods: Repeated unilateral detection of MES was performed by TCD in 20 patients supported with DeBakey LVAD. Each monitoring session consisted of 20 minutes without and 20 minutes with inhalation of 100% oxygen (6 l/min). A total of 500 MES, detected with (n=250) or without (n=250) the supply of oxygen, were randomly chosen for offline analysis. The SVL (in cm) was calculated by duration and velocity of the MES measured in the time domain mode. Additionally, frequency modulation of MES was classified into three main types: Without modulation (type I), with gradual changes (type II) and with rapid changes (type III).

Results: With oxygen supply, both prevalence (26.4% versus 36.2%, p<0.01) and mean counts of MES per hour (49±293 versus 108±550, p<0.001) significantly declined compared with the MES load while breathing room air. There was no significant difference in the SVL of MES under oxygen (0.85±0.38 cm) compared with those without oxygen delivery (0.92±0.37 cm, p=0.6). Furthermore, no significant differences were noted for the MES frequency modulation types in time domain analysis with regard to oxygen supply.

Conclusions: The reduction of MES under oxygen delivery confirms the gaseous nature in a substantial number of circulating microemboli produced by the DeBakey LVAD. However, SVL and frequency modulation of MES did not appear to provide valuable information regarding the structural nature of the underlying microembolic material.

Keywords: THROMBOEMBOLISM; TRANSCRANIAL DOPPLER ULTRASOUND; LEFT VENTRICULAR ASSIST DEVICE; MICROEMBOLIC SIGNALS; TIME DOMAIN ANALYSIS

Document Type: Research article

DOI: 10.1179/016164105X39950

Affiliations: 1: Department of Neurology, University of Münster, Münster, Germany 2: Department of Thoracic and Cardiovascular Surgery, University of Münster, Münster, Germany

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$51.00 plus tax      Refund Policy

 

OR

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A