A new method of extrapolating the sweep pattern visual evoked potential acuity

Authors: Zhou, Peng1; Zhao, Ming-Wei1; Li, Xiao-Xin2; Hu, Xiao-Feng3; Wu, Xi1; Niu, Lan-Jun1; Yu, Wen-Zhen1; Xu, Xiu-Lan1

Source: Documenta Ophthalmologica, Volume 117, Number 2, September 2008 , pp. 85-91(7)

Publisher: Springer

Purchase options

The full text electronic article is available for purchase. You will be able to download the full text electronic article after payment.

$47.00 plus tax      Refund Policy

OR

 
More like this?
Content Key:
Free Content - Free
New Content - New
Open Access Content - Open Access
Subscribed Content - Subscribed
Free Trial Content - Free Trial

Abstract:

Purpose In order to compare the amplitude-spatial frequency (A-SP) regression method with amplitude-logVA (A-logVA) regression methods in extrapolating the sweep pattern visual evoked potential (SPVEP) acuity. Methods We measured SPVEPs in 21 children and three adults using sinusoidally-modulated horizontal gratings as stimuli. The responses were averaged and displayed through discrete Fourier transformations. SPVER acuity was then estimated by using both the SPVEP amplitude- spatial frequency function (A-SP function regression method) and the SPVEP amplitude-log visual-angle function (A-logVA function regression method). Furthermore, the Bailey Lovie logMAR chart was employed to define visual acuity. Curve estimates were calculated to derive a correlation index (R) for each method. Results There are significant differences (t = 2.71, P < 0.05) between the correlation indices of curves obtained using the A-logVA function (logarithmic model, 0.95 ± 0.01) and that obtained by the A-SP function (inverse model, 0.92 ± 0.02). The overall correlation coefficient (r) between logMAR acuity and acuity calculated by the A-logVA regression method was 0.32 (P < 0.05). The overall correlation coefficient (r) between logMAR acuity and acuity calculated by the A-SP regression method was 0.41 (P < 0.05). Paired t-tests show that SPVEP acuity from the A-logVA function was not significantly different from acuities of the logMAR function (t = 1.77, P = 0.09). The difference in their mean values is 0.14 ± 0.08. However, SPVEP acuity calculated using the A-SP function regression method is significantly different from the acuity calculated from the logMAR function (t = 10.09, P < 0.01). The difference in their mean values is 0.41 ± 0.04. Conclusions The amplitude-logVA function regression method is more accurate in estimating SPVEP acuity in normal subjects with good visual acuity.

Keywords: Sweep pattern visual evoked potential; LogMAR acuity; Visual acuity

Document Type: Research article

DOI: 10.1007/s10633-007-9095-4

Affiliations: 1: Department of Ophthalmology, Peking University People's Hospital, No. 11 South Avenue of XiZhiMen, XiCheng District, Beijing, 100044, P.R. China 2: Department of Ophthalmology, Peking University People's Hospital, No. 11 South Avenue of XiZhiMen, XiCheng District, Beijing, 100044, P.R. China, Email: drlixiaoxin@vip.sina.com 3: Department of Ophthalmology, Chaoyang Hospital, Beijing, 100020, China

Back to top

Content Key:
Free Content - Free
New Content - New
Open Access Content - Open Access
Subscribed Content - Subscribed
Free Trial Content - Free Trial
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in
Need to register?
Sign up here
Text size: A | A | A | A