A new method of extrapolating the sweep pattern visual evoked potential acuity

Authors: Zhou, Peng1; Zhao, Ming-Wei1; Li, Xiao-Xin2; Hu, Xiao-Feng3; Wu, Xi1; Niu, Lan-Jun1; Yu, Wen-Zhen1; Xu, Xiu-Lan1

Source: Documenta Ophthalmologica, Volume 117, Number 2, September 2008 , pp. 85-91(7)

Publisher: Springer

Buy & download fulltext article:

OR

Price: $47.00 plus tax (Refund Policy)

Abstract:

Purpose In order to compare the amplitude-spatial frequency (A-SP) regression method with amplitude-logVA (A-logVA) regression methods in extrapolating the sweep pattern visual evoked potential (SPVEP) acuity. Methods We measured SPVEPs in 21 children and three adults using sinusoidally-modulated horizontal gratings as stimuli. The responses were averaged and displayed through discrete Fourier transformations. SPVER acuity was then estimated by using both the SPVEP amplitude- spatial frequency function (A-SP function regression method) and the SPVEP amplitude-log visual-angle function (A-logVA function regression method). Furthermore, the Bailey Lovie logMAR chart was employed to define visual acuity. Curve estimates were calculated to derive a correlation index (R) for each method. Results There are significant differences (t = 2.71, P < 0.05) between the correlation indices of curves obtained using the A-logVA function (logarithmic model, 0.95 ± 0.01) and that obtained by the A-SP function (inverse model, 0.92 ± 0.02). The overall correlation coefficient (r) between logMAR acuity and acuity calculated by the A-logVA regression method was 0.32 (P < 0.05). The overall correlation coefficient (r) between logMAR acuity and acuity calculated by the A-SP regression method was 0.41 (P < 0.05). Paired t-tests show that SPVEP acuity from the A-logVA function was not significantly different from acuities of the logMAR function (t = 1.77, P = 0.09). The difference in their mean values is 0.14 ± 0.08. However, SPVEP acuity calculated using the A-SP function regression method is significantly different from the acuity calculated from the logMAR function (t = 10.09, P < 0.01). The difference in their mean values is 0.41 ± 0.04. Conclusions The amplitude-logVA function regression method is more accurate in estimating SPVEP acuity in normal subjects with good visual acuity.

Keywords: Sweep pattern visual evoked potential; LogMAR acuity; Visual acuity

Document Type: Research article

DOI: http://dx.doi.org/10.1007/s10633-007-9095-4

Affiliations: 1: Department of Ophthalmology, Peking University People's Hospital, No. 11 South Avenue of XiZhiMen, XiCheng District, Beijing, 100044, P.R. China 2: Department of Ophthalmology, Peking University People's Hospital, No. 11 South Avenue of XiZhiMen, XiCheng District, Beijing, 100044, P.R. China, Email: drlixiaoxin@vip.sina.com 3: Department of Ophthalmology, Chaoyang Hospital, Beijing, 100020, China

Publication date: 2008-09-01

Related content

Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content

Text size:

A | A | A | A
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages. print icon Print this page