New Micro- and Nanoelectrode Arrays for Biomedical Applications

Authors: Kleps, I.1; Angelescu, A.2; Vasilco, R.2; Dascalu, D.2

Source: Biomedical Microdevices, Volume 3, Number 1, 1 March 2001 , pp. 29-33(5)

Publisher: Springer

Abstract:

A very simple fabrication technology for a new electrode array architecture with pyramidal micro- or nano-electrodes (ultramicroelectrodes, or UME) is described in this paper. This technology is based on standard processes used in silicon device fabrication such as: silicon etching, metallic and dielectric film deposition. In order to release the dielectric material from the top of the pyramidal electrode, the photolithographic exposure takes place on the whole silicon surface without photolithographic mask. Different applications of these micro- and nano-electrode array in bio-medical field are presented.

Keywords: nanoelectrode array technology; biotechnology; nanotools

Document Type: Regular paper

Affiliations: 1: National Institute for Research and Development in Microtechnologies (IMT-Bucharest) P.O. Box 38-160, Bucharest, Romania 〈irinak@imt.ro〉 2: National Institute for Research and Development in Microtechnologies (IMT-Bucharest) P.O. Box 38-160, Bucharest, Romania

Links for this article