Clarification of reconstituted frozen orange juice concentrate by continuous flow centrifugation for limonin glucoside solid phase extraction

Authors: Breksa III, Andrew P; Manners, Gary D; Ibarra, Phil

Source: Journal of the Science of Food and Agriculture, Volume 88, Number 12, September 2008 , pp. 2213-2218(6)

Publisher: John Wiley & Sons, Ltd.

Buy & download fulltext article:

The full text article is not available for purchase.

The publisher only permits individual articles to be downloaded by subscribers.

Abstract:

BACKGROUND: The suitability of continuous flow centrifugation for the clarification of reconstituted frozen orange juice concentrate prior to its application to a solid phase extraction column for the isolation of limonin glucoside was evaluated. Clarification experiments spanning three flow rates (325, 588 and 875 mL min−1) and three rotor speeds (equivalent to 2130, 8521 and 19 172 × g) were conducted in a simple factorial design.

RESULTS: With increasing rotor speed or decreasing flow rate the average particle size, colour parameters (CIE L*, a*, b*) and residual solids in the resulting centrifugates were found to decrease, whereas juice characteristics including pH, conductivity, °Brix and limonin glucoside content were unchanged by the clarification process. Mean particle size in the resulting centrifugates ranged from 1.14 to 79.31 µm. The most effective clarification was obtained using a 325 mL min−1 flow rate in conjunction with the maximum rotor speed. Suitability of the centrifugates for processing by solid phase extraction was tested through a two-step process, in which the centrifugates were first screened using small columns, followed by application of the centrifugate to a larger self-packed column (6.5 cm × 20 cm) containing SP-70 Sepabeads.

CONCLUSION: Centrifugates from two conditions (325 and 588 mL min−1 at the maximum rotor speed) were suitable for direct application to both columns. It was found that up to 19 L of these centrifugates could be applied to the 6.5 cm × 20 cm column without clogging or experiencing a decrease in flow rate. Analysis of the column effluent revealed that 11 L of centrifugate was sufficient to saturate this column. Published in 2008 by John Wiley & Sons, Ltd.

Keywords: frozen orange juice concentrate; clarification; limonoid glucosides; isolation; processing

Document Type: Research article

DOI: http://dx.doi.org/10.1002/jsfa.3338

Publication date: 2008-09-01

More about this publication?
Related content

Tools

Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content

Text size:

A | A | A | A
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages. print icon Print this page