BACKGROUND: The mechanism of high-flow oxygen therapy and the pressures reached in the airway have not been defined. We hypothesized that the flow would generate a low continuous positive pressure, and that elevated flow rates in this model could produce moderate pressures. The objective of this study was to analyze the pressure generated by a high-flow oxygen therapy system in an experimental model of the pediatric airway. METHODS: An experimental in vitro study was performed. A high-flow oxygen therapy system was connected to 3 types of interface (nasal cannulae, nasal mask, and oronasal mask) and applied to 2 types of pediatric manikin (infant and neonatal). The pressures generated in the circuit, in the airway, and in the pharynx were measured at different flow rates (5, 10, 15, and 20 L/min). The experiment was conducted with and without a leak (mouth sealed and unsealed). Linear regression analyses were performed for each set of measurements. RESULTS: The pressures generated with the different interfaces were very similar. The maximum pressure recorded was 4 cm H2O with a flow of 20 L/min via nasal cannulae or nasal mask. When the mouth of the manikin was held open, the pressures reached in the airway and pharynxes were undetectable. Linear regression analyses showed a similar linear relationship between flow and pressures measured in the pharynx (pressure = −0.375 + 0.138 × flow) and in the airway (pressure = −0.375 + 0.158 × flow) with the closed mouth condition. CONCLUSIONS: According to our hypothesis, high-flow oxygen therapy systems produced a low-level CPAP in an experimental pediatric model, even with the use of very high flow rates. Linear regression analyses showed similar linear relationships between flow and pressures measured in the pharynx and in the airway. This finding suggests that, at least in part, the effects may be due to other mechanisms.

Keywords: continuous positive airway pressure; high-flow oxygen therapy; nasal cannulae; pediatrics; respiratory support

Document Type: Research Article

DOI: http://dx.doi.org/10.4187/respcare.01386

Affiliations: Pediatric Intensive Care Department, Hospital General Universitario Gregorio Marañón, Complutense University of Madrid, Madrid, Spain

Publication date: May 1, 2012

More about this publication?

Tools

Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content

Text size:

A | A | A | A
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages. print icon Print this page