Masimo Rad-57 Pulse CO-Oximeter™ for noninvasive carboxyhemoglobin measurement
Authors: Suner, Selim; McMurdy, John
Source: Expert Review of Medical Devices, Volume 6, Number 2, March 2009 , pp. 125-130(6)
Publisher: Expert Reviews
Abstract:
Noninvasive methods of body fluid chemical measurement have been expanding. New technologies are enabling the quantification of different compounds in the blood and interstitial tissues. One example of this is the pulse oximeter, which has facilitated the measurement of oxyhemoglobin rapidly and reliably without the requirement of blood-draws. The Masimo Rad-57 Pulse CO-Oximeter™ expanded the capabilities of pulse-oximetry to include measurements of carboxyhemoglobin and methemoglobin. This innovation has revolutionized the paradigm for detection of patients with CO poisoning. Previously, clinicians relied on historical information and patient signs and symptoms pointing to the possibility of CO exposure or toxicity. Only then would a blood test be ordered to measure carboxyhemoglobin levels. Since the presentation of CO poisoning is nonspecific and overlaps with many other conditions, and since the presence of environmental CO is often unknown, the detection of this condition was only possible in cases where the presence of CO was obvious or where the symptoms were severe. We now know, from studies conducted using the Rad-57, the only US FDA-approved device for noninvasive measurement of SpCO, that there are a significant number of patients who experience CO exposure but are nonsymptomatic. The Rad-57 provides a clinical justification for screening in the healthcare setting to identify patients with significant CO exposure who would otherwise be undetected.Keywords: carbon monoxide; noninvasive; poisoning; pulse CO-oximetry
Document Type: Research article
DOI: http://dx.doi.org/10.1586/17434440.6.2.125
Affiliations: 1: Associate Professor, Brown University; and, Director, Disaster Medicine and Emergency Preparedness, Department of Emergency Medicine; and, Chairman, Emergency Preparedness Committee, Rhode Island Hospital, Rhode Island Disaster Medical Assistance
Publication date: 2009-03-01
- Expert Review of Medical Devices provides commentary, analysis and debate for all professionals involved in research, development, testing and clinical use of devices.
- Editorial Board
- Information for Authors
- Submit a Paper
- Subscribe to this Title
- Information for Advertisers
- Terms & Conditions
- Information for Librarians
- Free Trials
- ingentaconnect is not responsible for the content or availability of external websites
- In this: publication
- By this: publisher
- In this Subject: Technology , Medicine , Medicine (General)
- By this author: Suner, Selim ; McMurdy, John

Shopping cart
Receive new issue alert
Get Permissions