Free Content Monitoring bacterial contamination in equine platelet concentrates obtained by the tube method in a clean laboratory environment under three different technical conditions

Authors: M. E. Álvarez, C. E. Giraldo and J. U. Carmona

Source: Equine Veterinary Journal

Publisher: Equine Veterinary Journal Ltd.

Abstract:

Reasons for performing study: There is a growing interest in the use of autologous platelet concentrates (PCs) as treatment for chronic musculoskeletal diseases in horses. However, there is no information on the risk of bacterial contamination during their preparation.

Objectives: To: 1) assess the risk of bacterial contamination in equine PCs obtained by the tube method under 3 technical conditions: a) in a laminar flow cabinet, in a clean laboratory environment both with (b) and without (c) Bunsen burner;2) identify the critical points of the process of PCs preparation with risk of bacterial contamination; and 3) identify the potential bacterial contaminants in the process and their antibiotic susceptibility.

Methods: Bacteriological samples were taken from: the skin (shaved or unshaved) of the venipuncture site in 15 horses, both before and after being disinfected; hands and throat of the operator; caps of the tubes where the blood was processed; environment where the equine blood samples were collected; laboratory environment; laminar flow cabinet; bacteriological stove; and PCs obtained under 3 technical conditions.

Results: Bacteria were isolated from nonaseptically prepared equine skin, hands and throat of the operator, and the place where the blood samples were taken. Bacteria were not isolated from tube caps, laboratory environment, laminar flow cabinet or PCs. The isolated bacteria were normal biota from equine skin, human skin and throat, and environmental contaminants. Of the isolated bacteria, 23% were resistant to penicillin, 19% to ampicillin, 2.12% to ceftiofur, 3.2% to sulphamethoxazole/trimethoprim and 1.1% to enrofloxacin. Resistance to amikacin and gentamicin was not seen.

Conclusions and potential relevance: Uncontaminated PCs can be obtained by the tube method in a clean laboratory environment without the need for either a laminar flow cabinet or a Bunsen burner. It is mandatory to perform the procedure following strict aseptic technique.

Document Type:

DOI: 10.2746/042516409X455221

Free content The full text is free.
View now:
download Monitoring bacterial contamination in equine platelet concentrates obtained by the tube method in a clean laboratory environment under three different technical conditions
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Text size: A | A | A | A