Combined Hemodilution and Hypotension Monitored with Jugular Bulb Oxygen Saturation, EEG, and ECG Decreases Transfusion Volume and Length of ICU Stay for Major Orthopedic Surgery
Authors: Shapira Y.; Gurman G.; Artru A.A.; Ousyscher I.E.; Lam A.M.; Kollender Y.; Meller I.
Source: Journal of Clinical Anesthesia, Volume 9, Number 8, December 1997 , pp. 643-649(7)
Publisher: Elsevier
Key:
- Free Content
- New Content
- Subscribed Content
- Free Trial Content
Keywords: Electroencephalogram; hemodilution; hypotension, intraoperative; intensive care unit; oxygen saturation, jugular bulb; surgery, orthopedic; transfusion