Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment logo Elsevier logo

Publisher: Elsevier

Related content
Volume 392, Number 1, 21 June 1997

< previous issue | all issues | next issue >

X-ray detectors based on multiwire proportional chambers
pp. 12-17(6)
Authors: Baru S.E.; Aulchenko V.M.; Babichev E.A.; Dubrovin M.S.; Groshev V.R.; Khabakhpashev A.G.; Nekhanevich E.L.; Porosev V.V.; Savinov G.A.; Shekhtman L.I.; Smykov L.; Talyshev A.A.; Titov V.M.; Ukraintsev Y.G.; Velikzhanin Y.S.; Zanevsky Y.V.

Multi-ring position-sensitive detector for registering small-angle neutron scattering
pp. 18-22(5)
Authors: Avdeev M.V.; Beskrovny A.I.; Bogdzel A.A.; Levchanovsky F.V.; Prikhodko V.I.

The leak microstructure, preliminary results
pp. 23-27(5)
Authors: Lombardi M.; Lombardi F.S.

The ''RAPID'' high rate large area X-ray detector system
pp. 32-41(10)
Authors: Lewis R.A.; Helsby W.I.; Jones A.O.; Hall C.J.; Parker B.; Sheldon J.; Clifford P.; Hillen M.; Sumner I.; Fore N.S.; Jones R.W.M.; Roberts K.M.

The Daresbury fast multi-wire linear X-ray detector system
pp. 42-46(5)
Authors: Lewis R.A.; Hall C.J.; Parker B.; Jones A.; Helsby W.; Sheldon J.W.; Clifford P.; Hillon M.; Fore N.

A large area, 2-D, high-pressure MWPC for wide angle X-ray diffraction
pp. 47-50(4)
Authors: Ortuno-Prados F.; Hall C.; Helsby W.; Jones A.; Lewis R.; Parker B.; Sheldon J.; Bazzano A.; Ubertini P.

Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment
pp. 51-54(4)
Authors: Bednarek B.; Jelen K.; Koperny S.; Kowalski T.Z.; Rulikowska-Zarebska E.; Zajac J.

A new microdosimetric instrument based on a proportional scintillation imaging chamber for heavy ion track investigation
pp. 55-61(7)
Authors: Suzuki M.; Takahashi T.; Kuwahara K.; Okada H.; Masuda K.

A large 2D PSD for thermal neutron detection
pp. 62-67(6)
Authors: Knott R.B.; Smith G.C.; Watt G.; Boldeman J.W.

Two-dimensional gaseous microstrip detector for thermal neutrons
pp. 73-79(7)
Authors: Vellettaz N.; Assaf J.E.; Oed A.

Gas gain in MSGCs with Ar/CO2/CF4 mixtures
pp. 80-82(3)
Authors: Jelen K.; Koperny S.; Kowalski T.Z.; Rulikowska-Zarebska E.; Zajac J.

A curved Micro-Strip Gas Counter for synchrotron radiation time resolved SAXS/WAXS experiments
pp. 83-88(6)
Authors: Zhukov V.; Udo F.; Marchena O.; Hartjes F.G.; van den Berg F.D.; Bras W.; Vlieg E.

Surface streamer breakdown mechanisms in microstrip gas counters
pp. 89-93(5)
Authors: Peskov V.; Ramsey B.D.; Fonte P.

Gas gain stability in MSGCs and MGCs at high-rate operation
pp. 94-98(5)
Authors: van den Berg F.D.; Daum C.; van Eijk B.; van Eijk C.W.E.; Hartjes F.G.; van der Marel J.; Udo F.; Zhukov V.

Recent advances in the construction and testing of MSGCs
pp. 99-104(6)
Authors: Barr A.; Bouclier R.; Capeans M.; Mea G.D.; Hoch M.; Million G.; Manzin G.; Ropelewski L.; Sauli F.

Simulation of MSGC signals and application to the front-end electronics for LHC experiments
pp. 109-114(6)
Authors: Clergeau J.-F.; Contardo D.; Haroutunian R.; Mirabito L.; Smadja G.

Performance of MSGC on diamond-coated glass
pp. 115-119(5)
Authors: Cicognani G.; Guerard B.; Oed A.

Simulation with ITS 3.0 of pulse heights and hit multiplicities in an MSGC
pp. 120-123(4)
Authors: Papanestis A.; Shehktman L.I.; Miller D.J.

Development of imaging microstrip gas chambers and measurement of the polarization of X-rays
pp. 124-126(3)
Authors: Ochi A.; Aoki S.; Nishi Y.; Tanimori T.

Lifetime characteristics of Micro-Strip Gas Chambers
pp. 127-130(4)
Authors: Duerdoth I.P.; Freestone J.; Lumb N.; Snow S.; Thompson R.J.

Further experimental results of gas microdot detectors
pp. 131-134(4)
Authors: Biagi S.F.; Bordas J.; Duxbury D.; Gabathuler E.

Performance of microstrip and microgap gas detectors at high pressure
pp. 135-139(5)
Authors: Fraga F.A.F.; Fraga M.M.F.R.; Marques R.F.; Margato L.M.S.; Goncalo J.R.; Policarpo A.J.P.L.; van Eijk C.W.E.; Hollander R.W.; van der Marel J.

Performance of three variants of micro-gap chambers
pp. 140-144(5)
Authors: Clergeau J.-F.; Contardo D.; Haroutunian R.; Mirabito L.; Smadja G.

Latest results from the multigap resistive plate chamber
pp. 145-149(5)
Authors: Zeballos E.C.; Crotty I.; Hatzifotiadou D.; Valverde J.L.; Williams M.C.S.; Zichichi A.

Resistive plate chambers with secondary electron emitters and microstrip readout
pp. 150-154(5)
Authors: Zeballos E.C.; Crotty I.; Hatzifotiadou D.; Valverde J.L.; Williams M.C.S.; Zichichi A.; Fonte P.; Peskov V.

Performance of a Resistive Plate Chamber operated in avalanche mode under 137Cs irradiation
pp. 155-160(6)
Authors: Abbrescia M.; Colaleo A.; Iaselli G.; Maggi M.; Marangelli B.; Natali S.; Nuzzo S.; Ranieri A.; Romano F.; Gianini G.; Ratti S.P.; Vitulo P.

Performance of the silicon detectors for the CMS barrel tracker
pp. 161-164(4)
Authors: CMS; Silvestris L.

Upgrade of DELPHI Microvertex detector in 1996
pp. 165-168(4)
Author: Stavitski I.

Development of a 128 channel silicon drift detector for spectroscopic purposes
pp. 169-172(4)
Authors: Valk H.; Huizenga J.; van Eijk C.W.E.; Hollander R.W.; Nanver L.K.; Sarro P.M.; van den Boogaard A.

A ''Bioscope'' system using double-sided silicon strip detectors and self-triggering read-out chips
pp. 173-177(5)
Authors: Overdick M.; Czermak A.; Fischer P.; Herzog V.; Kjensmo A.; Kugelmeier T.; Ljunggren K.; Nygard E.; Pietrzik C.; Schwan T.; Strand S.-E.; Straver J.; Weilhammer P.; Wermes N.; Yoshioka K.

Silicon strip detectors for LHC: Comprehensive process and device analysis
pp. 178-182(5)
Authors: Marina R.D.; Passeri D.; Ciampolini P.; Bilei G.M.

SYRMEP: an innovative detection system for soft X-rays
pp. 188-191(4)
Authors: Arfelli F.; Barbiellini G.; Bonvicini V.; Bravin A.; Cantatore G.; Castelli E.; Cristaudo P.; Di Michiel M.; Longo R.; Olivo A.; Pani S.; Pontoni D.; Poropat P.; Prest M.; Rashevsky A.; Tomasini F.; Tromba G.; Vacchi A.

A multiplicity-vertex detector for the PHENIX experiment at RHIC
pp. 192-196(5)
Authors: Kapustinsky J.; Boissevain J.; Bosze E.; Britton C.; Chang J.; Clark D.; Emery M.; Ericson N.; Fung S.Y.; Jacak B.; Jaffe D.; Marek L.; Seto R.; Simon-Gillo J.; Simpson M.; Smith R.; Sullivan J.; Takahashi Y.; van Hecke H.; Walker J.; Xu N.

Focal plane detector of the Dubna gas-filled recoil separator
pp. 197-201(5)
Authors: Tsyganov Y.S.; Subbotin V.G.; Polyakov A.N.; Sukhov A.M.; Iliev S.; Mezentsev A.N.; Vacatov D.V.

Noise characteristics in irradiated multiguard structures
pp. 202-205(4)
Authors: Da Rold M.; Paccagnella A.; Fardin P.; Bacchetta N.; Wheadon R.; Benetti P.; Bisello D.

Single-sided microstrip detector for high radiation doses
pp. 206-209(4)
Authors: Evensen L.; Westgaard T.

Evaluation of a digital X-ray detector based on a phosphor-coated CCD for mammography
pp. 210-213(4)
Authors: Taibi A.; Del Guerra A.; Gambaccini M.; Marziani M.; Tuffanelli A.

The development of high-speed 100 fps CCD camera
pp. 214-219(6)
Authors: Hoffberg M.; Laird R.; Lenkzsus F.; Liu C.; Rodricks B.; Gelbart A.

A CCD-based tissue imaging system
pp. 220-226(7)
Authors: MacDonald J.H.; Wells K.; Reader A.J.; Ott R.J.

A CCD system for UV imaging of biomolecules
pp. 227-232(6)
Authors: MacDonald J.H.; Mahon A.R.; Allers L.A.; Hassard J.F.; Mainwood A.; Ott R.J.

Cooled CCD camera with tapered fibre optics for electron microscopy
pp. 233-236(4)
Authors: Faruqi A.R.; Andrews H.N.

Self-triggered intensified CCD for high resolution alpha autoradiography (alphaSTIC): A quantitative and identificative approach
pp. 237-243(7)
Authors: Aubineau-Laniece I.; Charon Y.; Dorner G.; Franck D.; Henge-Napoli M.H.; Laniece P.; Mastrippolito R.; Pinot L.; Valentin L.

An interpolating 2D pixel readout structure for synchrotron X-ray diffraction in protein crystallography
pp. 244-248(5)
Authors: Besch H.J.; Junk M.; Meiszner W.; Sarvestani A.; Stiehler R.; Walenta A.H.

Study of a DEPJFET pixel matrix with continuous clear mechanism
pp. 254-259(6)
Authors: Klein P.; Cesura G.; Fischer P.; Lutz G.; Neeser W.; Richter R.H.; Wermes N.

High efficiency pixellated CdTe detector
pp. 260-263(4)
Authors: Bennett P.R.; Shah K.S.; Klugerman M.; Squillante M.R.

X-ray response of germanium microstrip detectors with energy and position resolution
pp. 264-268(5)
Authors: Rossi G.; Morse J.; Labiche J.-C.; Protic D.; Owens A.R.

Recent results on GaAs detectors
pp. 269-273(5)
Authors: RD8; Bates R.L.; Campbell M.; D'Auria S.; Da Via C.; O'Shea V.; Raine C.; Smith K.M.

Preliminary results from CVD diamond detectors for biomolecular imaging
pp. 274-280(7)
Authors: Mahon A.R.; Allers L.; Ott R.J.; Hassard J.F.; Mainwood A.

CVD diamond detectors as dosimeters for radiotherapy
pp. 281-284(4)
Authors: Buttar C.M.; Conway J.; Meyfarth R.; Scarsbrook G.; Sellin P.J.; Whitehead A.

Development of inorganic scintillators
pp. 285-290(6)
Author: van Eijk C.W.E.

Development of a high-resolution alpha camera
pp. 291-294(4)
Authors: Yamamoto S.; Iida T.; Kanno I.

Scintillating array gamma camera for clinical use
pp. 295-298(4)
Authors: Pani R.; Pellegrini R.; Scopinaro F.; Soluri A.; De Vincentis G.; Pergola A.; Iacopi F.; Corona A.; Grammatico A.; Filippi S.; Ballesio P.L.

Coincident radiation imaging of iodine 125 for in vivo gene imaging in small animals
pp. 299-303(5)
Authors: Weisenberger A.G.; Majewski S.; Saha M.; Bradley E.

Performance of a long plastic scintillator detector for neutron studies
pp. 304-309(6)
Authors: Celano L.; Tagliente G.; D'Erasmo G.; Pantaleo A.; Colonna N.; Fiore E.M.; Rui R.

A LaF3: Nd(10%) scintillation detector with microgap gas chamber read-out for the detection of gamma-rays
pp. 310-314(5)
Authors: van der Marel J.; Bom V.R.; van Eijk C.W.E.; Hollander R.W.; Sarro P.M.

Pixelated neutron scintillation detectors using fibre optic coded arrays
pp. 315-318(4)
Authors: Rhodes N.J.; Wardle A.G.; Boram A.J.; Johnson M.W.

New generation position-sensitive PMT for nuclear medicine imaging
pp. 319-323(5)
Authors: Pani R.; Pergola A.; Pellegrini R.; Soluri A.; De Vincentis G.; Filippi S.; Di Domenico G.; Del Guerra A.; Scopinaro F.

Gamma and beta intra-operative imaging probes
pp. 324-329(6)
Authors: Hoffman E.J.; Tornai M.P.; Levin C.S.; MacDonald L.R.; Siegel S.

An investigation into the use of a microchannel plate as the photocathode for an SEE X-ray detector
pp. 330-335(6)
Authors: Hall C.J.; Lewis R.A.; Fraser G.; Duxbury D.; Pearson J.; Helsby W.; Jones A.; Sheldon J.W.; Parker B.

A fast and flexible multichannel electron detector with parallel readout for photoelectron spectroscopy
pp. 345-348(4)
Authors: Manning P.P.; Clague N.J.; Kirkman I.W.; Quinn F.M.; Hicks P.J.

Direct beta autoradiography using microchannel plate (MCP) detectors
pp. 349-353(5)
Authors: Lees J.E.; Fraser G.W.; Dinsdale D.

Spatial uniformity and UV sensitivity of microsphere plates (MSPs)
pp. 354-358(5)
Authors: Tremsin A.S.; Pearson J.F.; Lees J.E.; Fraser G.W.; Korobov V.; Shariv I.

Uses of microchannel plate intensified detectors for imaging applications in the X-ray, EUV and visible wavelength regions
pp. 359-363(5)
Authors: Read P.D.; Carter M.K.; Pike C.D.; Harrison R.A.; Kent B.J.; Swinyard B.M.; Patchett B.E.; Redfern R.M.; Shearer A.; Colhoun M.

Further microsphere plate studies
pp. 364-368(5)
Authors: Worth L.B.C.; Lapington J.S.; Trow M.W.

Front end electronics for high rate microstrip gaseous chamber readout
pp. 369-374(6)
Authors: Lange A.; Rost M.; Sack A.; Walenta A.H.

Fast PC-based data acquisition system for gas-filled position sensitive detectors
pp. 384-391(8)
Authors: Mio H.; Chemloul M.; Laggner P.; Amenitsch H.; Bernstorff S.; Rappolt M.

A digital readout system for the SYRMEP silicon strip detectors
pp. 392-395(4)
Authors: Arfelli F.; Barbiellini G.; Bonvicini V.; Bravin A.; Cantatore G.; Castelli E.; Cristaudo P.; Di Michiel M.; Longo R.; Olivo A.; Pani S.; Pontoni D.; Poropat P.; Prest M.; Rashevsky A.; Tomasini F.; Tromba G.; Vacchi A.; Vallazza E.

Position sensitive detectors for medical imaging
pp. 396-401(6)
Author: Ott R.J.

Construction and calibration of detectors for high-resolution metabolic breast cancer imaging
pp. 402-406(5)
Authors: Robar J.L.; Thompson C.J.; Murthy K.; Clancy R.; Bergman A.M.

Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photo sensitive wire chamber
pp. 407-413(7)
Authors: Bruyndonckx P.; Xuan L.; Tavernier S.; Shuping Z.

Performance characterisation of large area BaF2-TMAE detectors for use in a whole body clinical PET camera
pp. 414-420(7)
Authors: Visvikis D.; Ott R.J.; Wells K.; Flower M.A.; Stephenson R.; Bateman J.E.; Connolly J.

Developments in particle tracking using the Birmingham Positron Camera
pp. 421-426(6)
Authors: Parker D.J.; Allen D.A.; Benton D.M.; Fowles P.; McNeil P.A.; Tan M.; Beynon T.D.

Performance study of liquid xenon detector for PET
pp. 427-432(6)
Authors: Chepel V.; Lopes M.I.; Kuchenkov A.; Marques R.F.; Policarpo A.J.P.L.

An inexpensive PSD for heavy-ion elastic scattering measurements
pp. 447-449(3)
Authors: Alfaro-Molina R.; Belmont-Moreno E.; Martinez-Davalos A.; Menchaca-Rocha A.; Michaelian K.; Hagel K.; Li J.; Mdeiwayeh N.; Natowitz J.B.; Wada R.; Zhao Y.; Majka Z.

The application of position-sensitive detectors in multi-phase flow measurement
pp. 450-455(6)
Authors: Barratt I.; Byrne B.; Mennell J.; Yan Y.

Application of the electron-counting method to low-Z elemental analysis
pp. 465-470(6)
Authors: Pansky A.; Breskin A.; Chechik R.; Garty G.; Klein E.

Large area neutron and X-ray image-plate detectors for macromolecular biology
pp. 471-474(4)
Authors: Cipriani F.; Castagna J.-C.; Claustre L.; Wilkinson C.; Lehmann M.S.

Single shot dual energy reverse geometry X-radiography
pp. 475-478(4)
Authors: Wojcik R.; Majewski S.

< previous issue | all issues | next issue >

Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content

Text size:

A | A | A | A
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages. print icon Print this page