Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment logo Elsevier logo

Publisher: Elsevier

Volume 392, Number 1, 21 June 1997
Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

< previous issue | next issue > | all issues

X-ray detectors based on multiwire proportional chambers
pp. 12-17(6)
Authors: Baru S.E.; Aulchenko V.M.; Babichev E.A.; Dubrovin M.S.; Groshev V.R.; Khabakhpashev A.G.; Nekhanevich E.L.; Porosev V.V.; Savinov G.A.; Shekhtman L.I.; Smykov L.; Talyshev A.A.; Titov V.M.; Ukraintsev Y.G.; Velikzhanin Y.S.; Zanevsky Y.V.

Multi-ring position-sensitive detector for registering small-angle neutron scattering
pp. 18-22(5)
Authors: Avdeev M.V.; Beskrovny A.I.; Bogdzel A.A.; Levchanovsky F.V.; Prikhodko V.I.

The leak microstructure, preliminary results
pp. 23-27(5)
Authors: Lombardi M.; Lombardi F.S.

The ''RAPID'' high rate large area X-ray detector system
pp. 32-41(10)
Authors: Lewis R.A.; Helsby W.I.; Jones A.O.; Hall C.J.; Parker B.; Sheldon J.; Clifford P.; Hillen M.; Sumner I.; Fore N.S.; Jones R.W.M.; Roberts K.M.

The Daresbury fast multi-wire linear X-ray detector system
pp. 42-46(5)
Authors: Lewis R.A.; Hall C.J.; Parker B.; Jones A.; Helsby W.; Sheldon J.W.; Clifford P.; Hillon M.; Fore N.

A large area, 2-D, high-pressure MWPC for wide angle X-ray diffraction
pp. 47-50(4)
Authors: Ortuno-Prados F.; Hall C.; Helsby W.; Jones A.; Lewis R.; Parker B.; Sheldon J.; Bazzano A.; Ubertini P.

Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment
pp. 51-54(4)
Authors: Bednarek B.; Jelen K.; Koperny S.; Kowalski T.Z.; Rulikowska-Zarebska E.; Zajac J.

A new microdosimetric instrument based on a proportional scintillation imaging chamber for heavy ion track investigation
pp. 55-61(7)
Authors: Suzuki M.; Takahashi T.; Kuwahara K.; Okada H.; Masuda K.

A large 2D PSD for thermal neutron detection
pp. 62-67(6)
Authors: Knott R.B.; Smith G.C.; Watt G.; Boldeman J.W.

Two-dimensional gaseous microstrip detector for thermal neutrons
pp. 73-79(7)
Authors: Vellettaz N.; Assaf J.E.; Oed A.

Gas gain in MSGCs with Ar/CO2/CF4 mixtures
pp. 80-82(3)
Authors: Jelen K.; Koperny S.; Kowalski T.Z.; Rulikowska-Zarebska E.; Zajac J.

A curved Micro-Strip Gas Counter for synchrotron radiation time resolved SAXS/WAXS experiments
pp. 83-88(6)
Authors: Zhukov V.; Udo F.; Marchena O.; Hartjes F.G.; van den Berg F.D.; Bras W.; Vlieg E.

Surface streamer breakdown mechanisms in microstrip gas counters
pp. 89-93(5)
Authors: Peskov V.; Ramsey B.D.; Fonte P.

Gas gain stability in MSGCs and MGCs at high-rate operation
pp. 94-98(5)
Authors: van den Berg F.D.; Daum C.; van Eijk B.; van Eijk C.W.E.; Hartjes F.G.; van der Marel J.; Udo F.; Zhukov V.

Recent advances in the construction and testing of MSGCs
pp. 99-104(6)
Authors: Barr A.; Bouclier R.; Capeans M.; Mea G.D.; Hoch M.; Million G.; Manzin G.; Ropelewski L.; Sauli F.

Simulation of MSGC signals and application to the front-end electronics for LHC experiments
pp. 109-114(6)
Authors: Clergeau J.-F.; Contardo D.; Haroutunian R.; Mirabito L.; Smadja G.

Performance of MSGC on diamond-coated glass
pp. 115-119(5)
Authors: Cicognani G.; Guerard B.; Oed A.

Simulation with ITS 3.0 of pulse heights and hit multiplicities in an MSGC
pp. 120-123(4)
Authors: Papanestis A.; Shehktman L.I.; Miller D.J.

Development of imaging microstrip gas chambers and measurement of the polarization of X-rays
pp. 124-126(3)
Authors: Ochi A.; Aoki S.; Nishi Y.; Tanimori T.

Lifetime characteristics of Micro-Strip Gas Chambers
pp. 127-130(4)
Authors: Duerdoth I.P.; Freestone J.; Lumb N.; Snow S.; Thompson R.J.

Further experimental results of gas microdot detectors
pp. 131-134(4)
Authors: Biagi S.F.; Bordas J.; Duxbury D.; Gabathuler E.

Performance of microstrip and microgap gas detectors at high pressure
pp. 135-139(5)
Authors: Fraga F.A.F.; Fraga M.M.F.R.; Marques R.F.; Margato L.M.S.; Goncalo J.R.; Policarpo A.J.P.L.; van Eijk C.W.E.; Hollander R.W.; van der Marel J.

Performance of three variants of micro-gap chambers
pp. 140-144(5)
Authors: Clergeau J.-F.; Contardo D.; Haroutunian R.; Mirabito L.; Smadja G.

Latest results from the multigap resistive plate chamber
pp. 145-149(5)
Authors: Zeballos E.C.; Crotty I.; Hatzifotiadou D.; Valverde J.L.; Williams M.C.S.; Zichichi A.

Resistive plate chambers with secondary electron emitters and microstrip readout
pp. 150-154(5)
Authors: Zeballos E.C.; Crotty I.; Hatzifotiadou D.; Valverde J.L.; Williams M.C.S.; Zichichi A.; Fonte P.; Peskov V.

Performance of a Resistive Plate Chamber operated in avalanche mode under 137Cs irradiation
pp. 155-160(6)
Authors: Abbrescia M.; Colaleo A.; Iaselli G.; Maggi M.; Marangelli B.; Natali S.; Nuzzo S.; Ranieri A.; Romano F.; Gianini G.; Ratti S.P.; Vitulo P.

Performance of the silicon detectors for the CMS barrel tracker
pp. 161-164(4)
Authors: CMS; Silvestris L.

Upgrade of DELPHI Microvertex detector in 1996
pp. 165-168(4)
Author: Stavitski I.

Development of a 128 channel silicon drift detector for spectroscopic purposes
pp. 169-172(4)
Authors: Valk H.; Huizenga J.; van Eijk C.W.E.; Hollander R.W.; Nanver L.K.; Sarro P.M.; van den Boogaard A.

A ''Bioscope'' system using double-sided silicon strip detectors and self-triggering read-out chips
pp. 173-177(5)
Authors: Overdick M.; Czermak A.; Fischer P.; Herzog V.; Kjensmo A.; Kugelmeier T.; Ljunggren K.; Nygard E.; Pietrzik C.; Schwan T.; Strand S.-E.; Straver J.; Weilhammer P.; Wermes N.; Yoshioka K.

Silicon strip detectors for LHC: Comprehensive process and device analysis
pp. 178-182(5)
Authors: Marina R.D.; Passeri D.; Ciampolini P.; Bilei G.M.

SYRMEP: an innovative detection system for soft X-rays
pp. 188-191(4)
Authors: Arfelli F.; Barbiellini G.; Bonvicini V.; Bravin A.; Cantatore G.; Castelli E.; Cristaudo P.; Di Michiel M.; Longo R.; Olivo A.; Pani S.; Pontoni D.; Poropat P.; Prest M.; Rashevsky A.; Tomasini F.; Tromba G.; Vacchi A.

A multiplicity-vertex detector for the PHENIX experiment at RHIC
pp. 192-196(5)
Authors: Kapustinsky J.; Boissevain J.; Bosze E.; Britton C.; Chang J.; Clark D.; Emery M.; Ericson N.; Fung S.Y.; Jacak B.; Jaffe D.; Marek L.; Seto R.; Simon-Gillo J.; Simpson M.; Smith R.; Sullivan J.; Takahashi Y.; van Hecke H.; Walker J.; Xu N.

Focal plane detector of the Dubna gas-filled recoil separator
pp. 197-201(5)
Authors: Tsyganov Y.S.; Subbotin V.G.; Polyakov A.N.; Sukhov A.M.; Iliev S.; Mezentsev A.N.; Vacatov D.V.

Noise characteristics in irradiated multiguard structures
pp. 202-205(4)
Authors: Da Rold M.; Paccagnella A.; Fardin P.; Bacchetta N.; Wheadon R.; Benetti P.; Bisello D.

Single-sided microstrip detector for high radiation doses
pp. 206-209(4)
Authors: Evensen L.; Westgaard T.

Evaluation of a digital X-ray detector based on a phosphor-coated CCD for mammography
pp. 210-213(4)
Authors: Taibi A.; Del Guerra A.; Gambaccini M.; Marziani M.; Tuffanelli A.

The development of high-speed 100 fps CCD camera
pp. 214-219(6)
Authors: Hoffberg M.; Laird R.; Lenkzsus F.; Liu C.; Rodricks B.; Gelbart A.

A CCD-based tissue imaging system
pp. 220-226(7)
Authors: MacDonald J.H.; Wells K.; Reader A.J.; Ott R.J.

A CCD system for UV imaging of biomolecules
pp. 227-232(6)
Authors: MacDonald J.H.; Mahon A.R.; Allers L.A.; Hassard J.F.; Mainwood A.; Ott R.J.

Cooled CCD camera with tapered fibre optics for electron microscopy
pp. 233-236(4)
Authors: Faruqi A.R.; Andrews H.N.

Self-triggered intensified CCD for high resolution alpha autoradiography (alphaSTIC): A quantitative and identificative approach
pp. 237-243(7)
Authors: Aubineau-Laniece I.; Charon Y.; Dorner G.; Franck D.; Henge-Napoli M.H.; Laniece P.; Mastrippolito R.; Pinot L.; Valentin L.

An interpolating 2D pixel readout structure for synchrotron X-ray diffraction in protein crystallography
pp. 244-248(5)
Authors: Besch H.J.; Junk M.; Meiszner W.; Sarvestani A.; Stiehler R.; Walenta A.H.

Study of a DEPJFET pixel matrix with continuous clear mechanism
pp. 254-259(6)
Authors: Klein P.; Cesura G.; Fischer P.; Lutz G.; Neeser W.; Richter R.H.; Wermes N.

High efficiency pixellated CdTe detector
pp. 260-263(4)
Authors: Bennett P.R.; Shah K.S.; Klugerman M.; Squillante M.R.

X-ray response of germanium microstrip detectors with energy and position resolution
pp. 264-268(5)
Authors: Rossi G.; Morse J.; Labiche J.-C.; Protic D.; Owens A.R.

Recent results on GaAs detectors
pp. 269-273(5)
Authors: RD8; Bates R.L.; Campbell M.; D'Auria S.; Da Via C.; O'Shea V.; Raine C.; Smith K.M.

Preliminary results from CVD diamond detectors for biomolecular imaging
pp. 274-280(7)
Authors: Mahon A.R.; Allers L.; Ott R.J.; Hassard J.F.; Mainwood A.

CVD diamond detectors as dosimeters for radiotherapy
pp. 281-284(4)
Authors: Buttar C.M.; Conway J.; Meyfarth R.; Scarsbrook G.; Sellin P.J.; Whitehead A.

Development of inorganic scintillators
pp. 285-290(6)
Author: van Eijk C.W.E.

Development of a high-resolution alpha camera
pp. 291-294(4)
Authors: Yamamoto S.; Iida T.; Kanno I.

Scintillating array gamma camera for clinical use
pp. 295-298(4)
Authors: Pani R.; Pellegrini R.; Scopinaro F.; Soluri A.; De Vincentis G.; Pergola A.; Iacopi F.; Corona A.; Grammatico A.; Filippi S.; Ballesio P.L.

Coincident radiation imaging of iodine 125 for in vivo gene imaging in small animals
pp. 299-303(5)
Authors: Weisenberger A.G.; Majewski S.; Saha M.; Bradley E.

Performance of a long plastic scintillator detector for neutron studies
pp. 304-309(6)
Authors: Celano L.; Tagliente G.; D'Erasmo G.; Pantaleo A.; Colonna N.; Fiore E.M.; Rui R.

A LaF3: Nd(10%) scintillation detector with microgap gas chamber read-out for the detection of gamma-rays
pp. 310-314(5)
Authors: van der Marel J.; Bom V.R.; van Eijk C.W.E.; Hollander R.W.; Sarro P.M.

Pixelated neutron scintillation detectors using fibre optic coded arrays
pp. 315-318(4)
Authors: Rhodes N.J.; Wardle A.G.; Boram A.J.; Johnson M.W.

New generation position-sensitive PMT for nuclear medicine imaging
pp. 319-323(5)
Authors: Pani R.; Pergola A.; Pellegrini R.; Soluri A.; De Vincentis G.; Filippi S.; Di Domenico G.; Del Guerra A.; Scopinaro F.

Gamma and beta intra-operative imaging probes
pp. 324-329(6)
Authors: Hoffman E.J.; Tornai M.P.; Levin C.S.; MacDonald L.R.; Siegel S.

An investigation into the use of a microchannel plate as the photocathode for an SEE X-ray detector
pp. 330-335(6)
Authors: Hall C.J.; Lewis R.A.; Fraser G.; Duxbury D.; Pearson J.; Helsby W.; Jones A.; Sheldon J.W.; Parker B.

A fast and flexible multichannel electron detector with parallel readout for photoelectron spectroscopy
pp. 345-348(4)
Authors: Manning P.P.; Clague N.J.; Kirkman I.W.; Quinn F.M.; Hicks P.J.

Direct beta autoradiography using microchannel plate (MCP) detectors
pp. 349-353(5)
Authors: Lees J.E.; Fraser G.W.; Dinsdale D.

Spatial uniformity and UV sensitivity of microsphere plates (MSPs)
pp. 354-358(5)
Authors: Tremsin A.S.; Pearson J.F.; Lees J.E.; Fraser G.W.; Korobov V.; Shariv I.

Uses of microchannel plate intensified detectors for imaging applications in the X-ray, EUV and visible wavelength regions
pp. 359-363(5)
Authors: Read P.D.; Carter M.K.; Pike C.D.; Harrison R.A.; Kent B.J.; Swinyard B.M.; Patchett B.E.; Redfern R.M.; Shearer A.; Colhoun M.

Further microsphere plate studies
pp. 364-368(5)
Authors: Worth L.B.C.; Lapington J.S.; Trow M.W.

Front end electronics for high rate microstrip gaseous chamber readout
pp. 369-374(6)
Authors: Lange A.; Rost M.; Sack A.; Walenta A.H.

Fast PC-based data acquisition system for gas-filled position sensitive detectors
pp. 384-391(8)
Authors: Mio H.; Chemloul M.; Laggner P.; Amenitsch H.; Bernstorff S.; Rappolt M.

A digital readout system for the SYRMEP silicon strip detectors
pp. 392-395(4)
Authors: Arfelli F.; Barbiellini G.; Bonvicini V.; Bravin A.; Cantatore G.; Castelli E.; Cristaudo P.; Di Michiel M.; Longo R.; Olivo A.; Pani S.; Pontoni D.; Poropat P.; Prest M.; Rashevsky A.; Tomasini F.; Tromba G.; Vacchi A.; Vallazza E.

Position sensitive detectors for medical imaging
pp. 396-401(6)
Author: Ott R.J.

Construction and calibration of detectors for high-resolution metabolic breast cancer imaging
pp. 402-406(5)
Authors: Robar J.L.; Thompson C.J.; Murthy K.; Clancy R.; Bergman A.M.

Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photo sensitive wire chamber
pp. 407-413(7)
Authors: Bruyndonckx P.; Xuan L.; Tavernier S.; Shuping Z.

Performance characterisation of large area BaF2-TMAE detectors for use in a whole body clinical PET camera
pp. 414-420(7)
Authors: Visvikis D.; Ott R.J.; Wells K.; Flower M.A.; Stephenson R.; Bateman J.E.; Connolly J.

Developments in particle tracking using the Birmingham Positron Camera
pp. 421-426(6)
Authors: Parker D.J.; Allen D.A.; Benton D.M.; Fowles P.; McNeil P.A.; Tan M.; Beynon T.D.

Performance study of liquid xenon detector for PET
pp. 427-432(6)
Authors: Chepel V.; Lopes M.I.; Kuchenkov A.; Marques R.F.; Policarpo A.J.P.L.

An inexpensive PSD for heavy-ion elastic scattering measurements
pp. 447-449(3)
Authors: Alfaro-Molina R.; Belmont-Moreno E.; Martinez-Davalos A.; Menchaca-Rocha A.; Michaelian K.; Hagel K.; Li J.; Mdeiwayeh N.; Natowitz J.B.; Wada R.; Zhao Y.; Majka Z.

The application of position-sensitive detectors in multi-phase flow measurement
pp. 450-455(6)
Authors: Barratt I.; Byrne B.; Mennell J.; Yan Y.

Application of the electron-counting method to low-Z elemental analysis
pp. 465-470(6)
Authors: Pansky A.; Breskin A.; Chechik R.; Garty G.; Klein E.

Large area neutron and X-ray image-plate detectors for macromolecular biology
pp. 471-474(4)
Authors: Cipriani F.; Castagna J.-C.; Claustre L.; Wilkinson C.; Lehmann M.S.

Single shot dual energy reverse geometry X-radiography
pp. 475-478(4)
Authors: Wojcik R.; Majewski S.

< previous issue | next issue > | all issues

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A