Skip to main content

Median Sternotomy Closure in Dogs: A Mechanical Comparison of Technique Stability

Buy Article:

$48.00 plus tax (Refund Policy)

Abstract:

Objective

To evaluate the mechanical properties of canine median sternotomy closure using double-loop cerclage compared with other commonly used cerclage sternotomy closure patterns. Study Design

Experimental study. Sample Population

Forty canine cadaveric sternal segments. Methods

Median sternotomy-wire constructs were loaded to failure in a materials testing machine. Each construct was radiographed before and after testing. Specific wire configurations tested were: 2 single twist cerclage centered on the sternebrae, single twist figure of 8 pattern centered on the sternal synchondrosis, double twist figure of 8 pattern centered on the sternal synchondrosis, 2 double-loop cerclage centered on the sternebrae, and 1 double-loop cerclage centered on the sternal synchondrosis. Wire configurations were compared by craniocaudal translation of sternabrae on pre-test radiographs, and displacement during loading, and mode of failure, based on analysis of test video, and post-test radiographs. Results

Double-loop cerclage did not provide superior mechanical stabilization of median sternotomy. Both figure of 8 patterns had the least displacement at higher loads. Two single twists that were centered on sternebrae were least able to prevent displacement at higher loads, caused the most craniocaudal translation before testing, and fractured more often at loads ≤200 N compared with other configurations. Conclusion

Sternal wiring techniques stabilizing sternal synchondroses had the least displacement. Overall, figure of 8 cerclage appeared most suitable because they minimized displacement at high loads and facilitated accurate reduction during tensioning. Clinical Relevance

In closing canine sternotomy, figure of 8 cerclage may be most suitable. Double-loop cerclage centered on the sternal synchondrosis should be avoided because of wire failure at high loads.

Document Type: Research Article

DOI: http://dx.doi.org/10.1111/j.1532-950X.2006.00143.x

Affiliations: From the Department of Clinical Sciences, College of Veterinary Medicine and the Joint Department of Biomedical Engineering at UNC-Chapel Hill; and NC State University, North Carolina State University, Raleigh, NC

Publication date: April 1, 2006

bsc/vsu/2006/00000035/00000003/art00010
dcterms_title,dcterms_description,pub_keyword
6
5
20
40
5

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more