Increase of blood donation speed by optimizing the needle- to-tubing connection: an application of donation software

Authors: van der Meer, P. F.; de Korte, D.

Source: Vox Sanguinis, Volume 97, Number 1, July 2009 , pp. 21-25(5)

Publisher: Wiley-Blackwell

Buy & download fulltext article:

OR

Price: $48.00 plus tax (Refund Policy)

Abstract:

Background 

The speed of blood donation is affected by the resistance induced by the needle and tubing during collection. To increase blood donation speed, the connection between the needle and the tubing was modified. The aim was to evaluate the effect of this modification on various donation parameters. Methods 

Apart from the modified needle inset, the study systems were identical to reference bag systems routinely used in our centre, and only identifiable by their unique lot number. Blood collections were done at fixed sites under similar conditions using automated mixers. In total 8541 evaluable donations were performed in the reference group and 7430 in the study group. Electronically stored donation data were obtained from the mixers and used for analysis. Results 

The average donation speed increased from 63 ± 12 in the reference group to 75 ± 15 ml/min in the study group (P < 0·001), resulting in donation times of 8·10 ± 1·52 and 6·95 ± 1·48 min, respectively (P < 0·001). The number of units with a donation time greater than 12 min (which cannot be used for platelet production) halved in the study group. The percentage of donations with one or more donation alarms reduced from 22·2% in the reference group to 15·3% in the study group (P < 0·001). The number of adverse events (not feeling well, fainting) during donation did not increase. Conclusions 

The modification of the needle inset resulted in a 19% increase in donation speed, more units could be used for platelet production, and fewer flow alarms were encountered, while the number of adverse donor events remained unchanged.

Keywords: blood collection mixers; automation software; collection site efficiency

Document Type: Research article

DOI: http://dx.doi.org/10.1111/j.1423-0410.2009.01173.x

Publication date: 2009-07-01

Related content

Tools

Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content

Text size:

A | A | A | A
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages. print icon Print this page