Abstract Objective–

The primary objective of this study was to assess the feasibility of noninvasive mechanical ventilation (NIV) in cats. The secondary objective was to determine whether cardiovascular parameters and anesthetic drug requirements associated with noninvasive ventilation differ from those associated with invasive ventilation. Design–

Randomized, cross-over design. Setting–

A research laboratory in a veterinary teaching hospital. Animals–

Eight healthy adult cats, 3 intact females and 5 intact males, weighing between 3 and 6 kg, were used. Interventions–

Each cat was randomly assigned to NIV via nasal mask, or invasive ventilation using an endotracheal tube. Mechanical ventilation was performed for 6 hours. Anesthesia was provided using continuous infusions of propofol and butorphanol. After a minimum 9-day washout period, the procedure was repeated using the alternate ventilation interface. Measurements and Main Results–

Cardiovascular parameters (heart rate, rectal temperature, direct arterial blood pressure), arterial blood gases, drug requirements, sedation score, and ventilation parameters, were monitored throughout the procedures. These values were evaluated using ANCOVA for repeated measures. All cats were effectively ventilated using NIV. There were no significant differences in cardiovascular parameters, drug requirements, or sedation scores between groups. Although PaCO2 values did not differ, PaO2 values were significantly higher in the invasively ventilated group. Inspiratory tidal volumes were similar between groups, whereas expiratory tidal volumes were significantly lower in the NIV group. Inspiratory pressures were significantly higher in the NIV group. Respiratory frequency was significantly higher in the invasively ventilated group. Conclusions–

NIV of cats is possible. However, currently it does not confer any cardiovascular benefit over invasive ventilation and drug requirements are similar. Use of a correctly fitted mask is essential for successful NIV as air leaks account for the observed discrepancy between inspiratory and expiratory volumes. Further investigation into this modality is warranted.

Keywords: NIV; NPPV; endotracheal intubation; feline; nasal mask

Document Type: Research Article

DOI: https://doi.org/10.1111/j.1476-4431.2009.00458.x

Affiliations: Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada

Publication date: 2009-10-01

  • Access Key
  • Free ContentFree content
  • Partial Free ContentPartial Free content
  • New ContentNew content
  • Open Access ContentOpen access content
  • Partial Open Access ContentPartial Open access content
  • Subscribed ContentSubscribed content
  • Partial Subscribed ContentPartial Subscribed content
  • Free Trial ContentFree trial content
Cookie Policy
X
Cookie Policy
Ingenta Connect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more