Free Content Photoplethysmography as a single source for analysis of sleep‐disordered breathing in patients with severe cardiovascular disease

You have access to the full text article on a website external to ingentaconnect.

Please click here to view this article on Wiley Online Library.

You may be required to register and activate access on Wiley Online Library before you can obtain the full text. If you have any queries please visit Wiley Online Library

Download Article:

Abstract:

Summary

Sleep‐disordered breathing and Cheyne–Stokes breathing are often not diagnosed, especially in cardiovascular patients. An automated system based on photoplethysmographic signals might provide a convenient screening and diagnostic solution for patient evaluation at home or in an ambulatory setting. We compared event detection and classification obtained by full polysomnography (the ‘gold standard’) and by an automated new algorithm system in 74 subjects. Each subject underwent overnight polysomnography, 60 in a hospital cardiology department and 14 while being tested for suspected sleep‐disordered breathing in a sleep laboratory. The sleep‐disordered breathing and Cheyne–Stokes breathing parameters measured by a new automated algorithm system correlated very well with the corresponding results obtained by full polysomnography. The sensitivity of the Cheyne–Stokes breathing detected from the system compared to full polysomnography was 92% [95% confidence interval (CI): 78.6–98.3%] and specificity 94% (95% CI: 81.3–99.3%). Comparison of the Apnea Hyponea Index with a cutoff level of 15 shows a sensitivity of 98% (95% CI: 87.1–99.6%) and specificity of 96% (95% CI: 79.8–99.3%). The detection of respiratory events showed agreement of approximately 80%. Regression and Bland–Altman plots revealed good agreement between the two methods. Relative to gold‐standard polysomnography, the simply used automated system in this study yielded an acceptable analysis of sleep‐ and/or cardiac‐related breathing disorders. Accordingly, and given the convenience and simplicity of its application, this system can be considered as a suitable platform for home and ambulatory screening and diagnosis of sleep‐disordered breathing in patients with cardiovascular disease.

Document Type: Research Article

DOI: http://dx.doi.org/10.1111/j.1365-2869.2011.00927.x

Affiliations: 1: Division of Cardiology, Lady Davis Carmel Medical Center, Haifa, Israel 2: WideMed Ltd, Herzliya, Israel 3: Morristown Memorial Hospital, Morristown, NJ, USA

Publication date: February 1, 2012

Related content

Tools

Favourites

Share Content

Access Key

Free Content
Free content
New Content
New content
Open Access Content
Open access content
Subscribed Content
Subscribed content
Free Trial Content
Free trial content
Cookie Policy
X
Cookie Policy
ingentaconnect website makes use of cookies so as to keep track of data that you have filled in. I am Happy with this Find out more