Free Content Dose-effect relationship for several coagulation markers during administration of the direct thrombin inhibitor S 18326 in healthy subjects

Authors: Gaussem P.; Dubar M.; le Bonniec B.; Richard-Lordereau I.; Jochemsen R.; Aiach M.

Source: British Journal of Clinical Pharmacology, Volume 53, Number 2, February 2002 , pp. 147-154(8)

Publisher: Blackwell Publishing

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content

Abstract:

Aims

We conducted a phase I placebo-controlled trial with two i.v. doses (0.5 mg h-1 and 3 mg h-1) of S 18326, a selective thrombin inhibitor that interacts with the catalytic site of thrombin, with the aim to study the relationships between increasing plasma levels of S 18326 and changes in coagulation tests and thrombin generation markers.

Methods

Thirty-six healthy male volunteers were divided into three groups. In each group, 10 volunteers were randomly assigned to receive S 18326 and two to receive a placebo. Following a bolus of 4.5 mg, doses were 0.5 mg h-1 in the first group and 3 mg h-1 in the two other groups, administered as an i.v. infusion for 24 h. Blood was drawn repeatedly up to 36 h after the bolus, and tested for the activated clotting time (ACT) and activated partial thromboplastin time (APTT). The APTT reagent was chosen among five commercial reagents to yield a linear increase in the clotting time among possible therapeutic S 18326 concentrations in vitro. To accurately measure the thrombin-inhibiting effects of low doses of S 18326 (< 0.5 µm), we developed a specific chromogenic assay. We also measured F1 + 2 prothrombin fragment levels to assess the effect of S 18326 on thrombin generation in vivo.

Results

A two-compartment pharmacokinetic model was fitted to the S 18326 plasma concentration vs time data by using population pharmacokinetic methods. Results of the pharmacodynamic-pharmacokinetic relationships showed that both the ACT and APTT methods yielded a linear increase according to the S 18326 concentration measured using a highly sensitive analytical method. At the end of infusion, ACT was prolonged 1.20 and 1.95-fold in the 0.5 mg h-1 and the 3 mg h-1 groups, respectively, and APTT was prolonged 1.27 and 2.75-fold. Thrombin inhibition plateaued above 0.5 µm of S 18326 according to an Emax model, confirming that the test was highly sensitive. F1 + 2 levels fell significantly after the 24 h S 18326 infusion (0.83 nm to 0.6 nm and 0.80 nm to 0.44 nm in the 0.5 mg h-1 and the 3 mg h-1 groups, respectively), but remained stable after the placebo infusion.

Conclusions

Our results support specific monitoring of the thrombin inhibitor S 18326 with ACT and APTT to establish the safety range of the drug in further studies. Moreover, the fall in F1 + 2 prothrombin fragments suggests that S 18326 effectively reduces the retroactivation of factors V and VIII by thrombin.

Keywords: clotting tests; markers of coagulation activation; pharmacodynamics; pharmacokinetics; thrombin inhibitors

Language: English

Document Type: Research article

DOI: 10.0000/135048597355177

You have access to the full text article on a website external to Ingentaconnect.

Please click here to view this article on InterScience.

You may be required to register and activate access on InterScience before you can obtain the full text. If you have any queries please contact onlinehelp@oxon.blackwellpublishing.com

Back to top

Key:
Free Content - Free Content
New Content - New Content
Subscribed Content - Subscribed Content
Free Trial Content - Free Trial Content
Share this item with others: These icons link to social bookmarking sites where readers can share and discover new web pages.
Page Help Click here for Page Help
Shopping cart
Tools
Sign in






Need to register?
Sign up here
Text size: A | A | A | A