Design of an Artificial Left Ventricular Muscle: An Innovative Way to Actuate Blood Pumps?
Authors: Van Der Smissen, Benjamin; Claessens, Tom; Verdonck, Pascal1; Van Ransbeeck, Peter2; Segers, Patrick1
Source: Artificial Organs, Volume 33, Number 6, June 2009 , pp. 464-468(5)
Publisher: Wiley-Blackwell
Abstract:
Blood pumps assist or take over the pump function of a failing heart. They are essentially activated by a pusher plate, a pneumatic compression of collapsible sacs, or they are driven by centrifugal pumps. Blood pumps relying upon one of these actuator mechanisms do not account for realistic wall deformation. In this study, we propose an innovative design of a blood pump actuator device which should be able to mimic fairly well global left ventricular (LV) wall deformation patterns in terms of circumferential and longitudinal contraction, as well as torsion. In order to reproduce these basic wall deformation patterns in our actuator device, we designed a novel kind of artificial LV “muscle” composed of multiple actively contracting cells. Its contraction is based on a mechanism by which pressurized air, inside such a cell, causes contraction in one direction and expansion perpendicular to this direction. The organization and geometry of the contractile cells within one artificial LV muscle, the applied pressure in the cells, and the governing LV loading conditions (preload and afterload) together determine the global deformation of the LV wall. Starting from a simple plastic bag, an experimental model based on the abovementioned principle was built and connected to a lumped hydraulic model of the vascular system (including compliance and resistance). The wall deformation pattern of this device was validated visually and its pump performance was studied in terms of LV volume and pressure and heart rate. Our experimental results revealed (i) a global LV motion resembling a real LV, and (ii) a close correlation between our model and a real LV in terms of end-systolic volume and pressure, end-diastolic volume and pressure, stroke volume, ejection fraction and pressure-volume relationship. Our proposed model appears promising and it can be considered as a step forward when compared to currently applied actuator mechanisms, as it will likely result in more physiological intracavity blood flow patterns.Keywords: Actuator; Artificial; Blood pump; Contraction; Heart; Left ventricle; Muscle; Pneumatics; Torsion; Wall deformation
Document Type: Research article
DOI: http://dx.doi.org/10.1111/j.1525-1594.2009.00750.x
Affiliations: 1: Department of Civil Engineering, Institute Biomedical Technology, Ghent University, Belgium 2: Department of Mechanics, Biomechanics, University College Ghent; and
Publication date: 2009-06-01
- In this: publication
- By this: publisher
- In this Subject: Surgery
- By this author: Van Der Smissen, Benjamin ; Claessens, Tom ; Verdonck, Pascal ; Van Ransbeeck, Peter ; Segers, Patrick

Shopping cart
Receive new issue alert
Get Permissions