ISSN 0003-2409
Publisher: Wiley-Blackwell
< previous issue | all issues | next issue >
Of humans, factors, failings and fixations pp. 1-3(3) Author: Yentis, S.
Small change pp. 3-3(1) Author: Yentis, S.
The effect of pre-emptive use of minimal dose fentanyl on fentanyl-induced coughing pp. 4-7(4) Authors: Hung, K.-C.; Chen, C.-W.; Lin, V. C.-H.; Weng, H.-C.; Hsieh, S.-W.
The Parker Flex-Tip™ tube for nasotracheal intubation: the influence on nasal mucosal trauma pp. 8-11(4) Authors: Sanuki, T.; Hirokane, M.; Matsuda, Y.; Sugioka, S.; Kotani, J.
Atomised lidocaine for airway topical anaesthesia in the morbidly obese: 1% compared with 2% pp. 12-17(6) Authors: Woodruff, C.; Wieczorek, P. M.; Schricker, T.; Vinet, B.; Backman, S. B.
Validation of a novel fibreoptic intubation trainer pp. 18-22(5) Authors: Williams, D. J.; Byrne, A. J.; Bodger, O.
The prevalence of anatomical variations that can cause inadvertent dural puncture when performing caudal block in Koreans: a study using magnetic resonance imaging pp. 23-26(4) Authors: Joo, J.; Kim, J.; Lee, J.
HLA-DR expression and differential trafficking of monocyte subsets following low to intermediate risk surgery pp. 27-35(9) Authors: Handy, J. M.; Scott, A. J.; Cross, A. M.; Sinha, P.; O'Dea, K. P.; Takata, M.
Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin pp. 36-43(8) Authors: de Lloyd, L.; Hodzovic, I.; Voisey, S.; Wilkes, A. R.; Latto, I. P.
Monitoring of haemostasis in liver transplantation: comparison of laboratory based and point of care tests pp. 44-49(6) Authors: Herbstreit, F.; Winter, E. M.; Peters, J.; Hartmann, M.
Appropriate laryngeal mask airway size for overweight and underweight children pp. 50-53(4) Authors: Kim, H. J.; Park, M. J.; Kim, J. T.; Kim, C. S.; Kim, S. D.; Kim, H. S.
Radiation exposure to anaesthetists during interventional radiology pp. 54-60(7) Authors: Ismail, S.; Khan, F.; Sultan, N.; Naqvi, M.
No simple fix for fixation errors: cognitive processes and their clinical applications pp. 61-69(9) Authors: Fioratou, E.; Flin, R.; Glavin, R.
Unrecognised dural puncture resulting in subdural hygroma and cortical vein thrombosis pp. 70-73(4) Authors: Sinha, A.; Petkov, S.; Meldrum, D.
Peri-operative management of a patient with hereditary angioedema undergoing laparoscopic cholecystectomy pp. 74-77(4) Authors: Spyridonidou, A.; Iatrou, C.; Alexoudis, A.; Vogiatzaki, T.; Polychronidis, A.; Simopoulos, C.
Dental implant removal to facilitate suspension laryngoscopy and laser treatment of an obstructed airway pp. 78-81(4) Authors: Hume-Smith, H.; Fowler, A.; Vaz, F.; Suaris, P.
Do Not Attempt Resuscitation decisions in the peri-operative period pp. 82-82(1) Authors: Poplett, N.; Smith, G. B.
A reply pp. 82-83(2) Authors: McBrien, M.; Heyburn, G.
Ethical issues and donor numbers pp. 84-84(1) Authors: Cottle, D.; Dean, P.
Measuring operating theatre list efficiency requires acknowledgement of costs pp. 84-85(2) Authors: Siegmueller, C.; Herden-Kirchhoff, O.
A reply pp. 85-86(2) Authors: Pandit, J. J.; Stubbs, D.; Westbury, S.; Pandit, M.
Evidence base and intravenous fluids pp. 86-86(1) Author: Burdett, E.
A reply pp. 86-87(2) Authors: Morris, C.; Reynolds, N.; Boyd, A.
Is the cause of hypernatraemia in critically ill patients more obvious than we think? pp. 87-88(2) Authors: Silversides, J. A.; Quinn, L. D.; Parker, M. J.; Austin, S. J.
Raising the Standard… to unachievable heights? pp. 88-89(2) Authors: Noblet, J.; Plaat, F.
Lubrication of the i-gel supraglottic airway and the classic laryngeal mask airway pp. 89-89(1) Author: Chapman, D.
A reply pp. 89-89(1) Authors: Wilkes, A. R.; Janakiraman, C.; Goodwin, N.; Stacey, M. R.
Mitigation of rocuronium-induced anaphylaxis by sugammadex: the great unknown pp. 89-90(2) Authors: Jones, P. M.; Turkstra, T. P.
A reply pp. 90-90(1) Author: Harper, N. J. N.
Severe bronchospasm or anaphylaxis? pp. 90-91(2) Authors: Kant, A.; McKinlay, J.
Subcostal transversus abdominis plane block pp. 91-92(2) Authors: O'Connor, K.; Renfrew, C.
Peri-operative echocardiographic diagnosis of aortic stenosis pp. 92-93(2) Authors: Webb, S. T.; Klein, A. A.
BIS monitored day-case cardioversion: a comparison of sevoflurane with propofol pp. 94-94(1) Authors: Sharafudeen, S.; Rashid, A.; Khan, S. N.; Parsloe, M.
Does the transversus abdominis plane (TAP) block improve analgesia following subarachnoid anaesthesia with intrathecal diamorphine? A randomised double blinded control trial pp. 95-95(1) Authors: Puddy, E.; Edwards, B.; Wrench, I.; Roberts, F.
Effect of ethnicity on induction dose of propofol pp. 95-96(2) Authors: Pattanayak, R.; Natarajan, A.; Strandvik, G.; Chakithandy, S.; Passalacqua, A.; Morley, A. P.
`Do you have a stick in your mouth?'- use of Google Translate as an aid to anaesthetic pre-assessment pp. 96-97(2) Authors: Nguyen-Lu, N.; Reide, P.; Yentis, S. M.
Evaluation of the capnographic monitoring and oxygen delivery functions of three variable oxygen delivery masks pp. 97-98(2) Authors: Mani, M.; Maghur, H.; Mecklenburgh, J.; Hodzovic, I.
Motion analysis - a new technology in airway assessment pp. 98-99(2) Authors: Mani, M.; Roberts, M.; Curtis, E.; Goodwin, N.; Zatman, T.; Wilkes, A. R.; Holt, C.
Fasting periods and dehydration before elective caesarean section pp. 99-99(1) Authors: Mackenzie, M.; Yentis, S.; Woolnough, M.; Johnson, M.
Predicting blood loss using novel thromboelastometry assays in cardiac surgery pp. 99-100(2) Authors: Coakley, M.; Evans, C.; Collins, P.; Hall, J. E.
Improving work place assessments in anaesthesia pp. 100-101(2) Authors: Crossingham, G.; Sice, P.; Roberts, M.; Gale, T.; Lam, H.; Anderson, I.; Carr, A.; Davies, P.; Langton, J.
The accuracy of clocks and monitors in clinical areas throughout a district general hospital - an audit pp. 101-102(2) Authors: Topping, A.; Laird, R.
Accuracy of central venous catheter tip placement in relation to catheter length pp. 102-102(1) Author: Board, P.
Monitoring after neuraxial opioids for caesarean section: a survey of UK practice pp. 102-103(2) Authors: Campbell, J. P.; Sabharwal, A.; Harrop-Griffiths, W.; Malhotra, S.
An audit of resuscitation suction equipment in clinical areas at six hospitals across South Yorkshire pp. 103-104(2) Authors: Faulds, M. C.; Murray, R. J.
Medical students or consultants in anaesthesia - who would you want to resuscitate you? pp. 104-104(1) Authors: Thake, J. C.; Holdstock, C.; Casemore, M.; Ferguson, S.
Adequacies or inadequacies in midwifery post-anaesthetic recovery skills pp. 104-105(2) Authors: Gandre, P.; Chitre, S.
A 9-year audit of co-morbidities and their impact on mortality in patients with hip fractures pp. 105-106(2) Authors: Goon, S.; Nathanson, M. H.; Boulton, C.; Moran, C.
Transparency of UK anaesthetic organisations pp. 106-107(2) Authors: Griffiths, S.; Yentis, S. M.
Regional audit - availability of equipment and training in emergency cricothyroidotomy pp. 107-107(1) Authors: Hargreaves, S.; Lacasia, C.; Groom, P.
A regional audit of experience managing C1 esterase inhibitor deficiency - cause of a potential airway emergency pp. 108-108(1) Authors: Hawe, C. S.; Shields, M.; Edgar, D.
`Decision to delivery'- assessment of maternity staff communication with anaesthetists in preparation for emergency caesarean sections pp. 108-109(2) Authors: Thillaisundaram, A.; Howie, K.; Henderson, F.; O'Connor, R.
Interobserver variability in determination of anaerobic threshold by cardiopulmonary exercise testing pp. 109-110(2) Authors: Patrick, K.; Sneyd, J. R.; Challand, C.; Erasmus, P.; Struthers, R.; Minto, G.
Service evaluation of pre-oxygenation for emergency surgery under general anaesthesia pp. 110-110(1) Authors: Philips, A. S.; Wrench, I. J.; Freeman, R.
The use of Intralipid for unconsciosness after a mixed overdose pp. 110-111(2) Authors: Oti, C.; Uncles, D.; Sable, N.; Willers, J.
Use of the neonatal GlideScope® in the management of acute upper airway obstruction pp. 111-112(2) Authors: Griffiths, S.; Graham, B.; Brooks, P.
Reversible blindness associated with severe diabetic ketoacidosis pp. 112-112(1) Authors: Ali, M. A.; Sanaullah, A.; Temblett, P. E.
Laparoscopic insertion of a diaphragmatic pacing system in patients with non-spinal injury-related neurological respiratory failure: the first reported UK cases pp. 112-113(2) Authors: Philips, A.; Englert, L.; Ackroyd, R.; Shaw, P. J.; Mc Dermott, C.
Finding the charts pp. 114-114(1) Authors: Shanmugasundaram, P.; Sellers, W. F. S.